Access via the batch mode

The firmware is automatically loaded onto a target system by entering a command line in "batch mode". The target system is an inverter, communication module or a controller from Lenze.

This type of access is ideal for series commissioning or integration into a third-party system.

Warning!

After the firmware download, the inverter is re-initialised.

Make sure that the drive does not start up uncontrollably afterwards. If possible, lock the controller via the terminal.

What is "batch mode"?

A command line contains the required communication settings and details of the target devices.

Note the following behaviour in "Batch mode":

  • Automatic activation of the controller lock in the target system!

  • Automatic stop of the running PLC programme in the target system!

  • The output of messages in the "Note" and "Information" categories is partially suppressed.