Parameter set configuration
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x4041:001 ... 0x4041:032
(P750.01 ... 32)
|
Parameter change-over: Parameter 1 ... Parameter 32
(Param.set setup: Parameter 1 ... Parameter 32)
0x00000000 ... [0x00000000] ... 0xFFFFFF00
|
Definition of the parameter list for the "Parameter change-over" function.
–
Format: 0xiiiiss00 (iiii = hexadecimal index, ss = hexadecimal subindex)
–
The lowest byte is always 0x00.
|
|
|
0x4042:001 ... 0x4042:032
(P751.01 ... 32)
|
Parameter value set 1: Value of parameter 1 ... Value of parameter 32
(Par. value set 1: Set 1 - Value 1 ... Set 1 - Value 32)
-2147483648 ... [0] ... 2147483647
|
Value set 1 for the parameter list defined in 0x4041:001 ... 0x4041:032 (P750.01 ... 32).
|
|
|
0x4043:001 ... 0x4043:032
(P752.01 ... 32)
|
Parameter value set 2: Value of parameter 1 ... Value of parameter 32
(Par. value set 2: Set 2 - Value 1 ... Set 2 - Value 32)
-2147483648 ... [0] ... 2147483647
|
Value set 2 for the parameter list defined in 0x4041:001 ... 0x4041:032 (P750.01 ... 32).
|
|
|
0x4044:001 ... 0x4044:032
(P753.01 ... 32)
|
Parameter value set 3: Value of parameter 1 ... Value of parameter 32
(Par. value set 3: Set 3 - Value 1 ... Set 3 - Value 32)
-2147483648 ... [0] ... 2147483647
|
Value set 3 for the parameter list defined in 0x4041:001 ... 0x4041:032 (P750.01 ... 32).
|
|
|
0x4045:001 ... 0x4045:032
(P754.01 ... 32)
|
Parameter value set 4: Value of parameter 1 ... Value of parameter 32
(Par. value set 4: Set 4 - Value 1 ... Set 4 - Value 32)
-2147483648 ... [0] ... 2147483647
|
Value set 4 for the parameter list defined in 0x4041:001 ... 0x4041:032 (P750.01 ... 32).
|
|
|
0x4047:001
(P756.01)
|
Parameter change-over error message: Status
(PSet error msg.: Status)
–
Read only
|
Error message for the "parameter change-over" function.
–
In the event of an error, an error status is shown here, and in 0x4047:002 (P756.02) the number of the list entry in which the error has occurred is displayed (in connection with the value set selected).
–
If several errors occur at the same time, only the first incorrect list entry will be displayed. Hence, after elimination of the displayed error and repeated activation, more errors may be displayed.
–
The parameter list will always be processed from beginning to end, even if errors occur in the meantime.
|
|
|
0
|
No fault
|
||
|
33803
|
Invalid data type
|
||
|
33804
|
Range violation
|
||
|
33806
|
Invalid index
|
||
|
33813
|
No element selected
|
||
|
33815
|
Writing impermissible
|
||
|
33816
|
Device not inhibited
|
||
|
33829
|
Invalid subindex
|
||
|
33837
|
Access impermissible
|
||
|
33860
|
Parameter not mappable
|
||
|
33865
|
No subindexes
|
||
|
33876
|
Parameter not changeable
|
||
|
0x4047:002
(P756.02)
|
Parameter change-over error message: List entry
(PSet error msg.: List entry)
–
Read only
|
Error message for the "Parameter set changeover" function.
–
In the event of an error, the number of the list entry for which the error displayed in 0x4047:001 (P756.01) has occurred is shown here.
|
|