Monitoring

The parameters for setting network monitoring functions are described below.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x10F3:001
Diagnosis History: Maximum Messages
–
Read only
 
–
From version 03.00
 
Maximum number of messages that can be stored in the history buffer (from subindex 6).
0x10F3:002
Diagnosis History: Newest Message
–
Read only
 
–
From version 03.00
 
Subindex of the latest message.
0x10F3:003
Diagnosis History: Newest Acknowledged Message
0 ... [0] ... 255
–
From version 03.00
 
Subindex of the latest message acknowledged by the EtherCAT master.
0x10F3:004
Diagnosis History: New message available
–
Read only
 
–
From version 03.00
 
TRUE if messages are available that have not been acknowledged yet by the EtherCAT master.
0x10F3:005
Diagnosis History: Flags
0 ... [1] ... 65535
–
From version 03.00
 
Settings for sending and saving of the messages.
0x10F3:006
Diagnosis History: Diagnosis message 0
–
Read only
 
–
From version 03.00
 
0x10F3:007
Diagnosis History: Diagnosis message 1
–
Read only
 
–
From version 03.00
 
0x10F3:008
Diagnosis History: Diagnosis message 2
–
Read only
 
–
From version 03.00
 
0x10F3:009
Diagnosis History: Diagnosis message 3
–
Read only
 
–
From version 03.00
 
0x10F3:010
Diagnosis History: Diagnosis message 4
–
Read only
 
–
From version 03.00
 
0x10F3:011
Diagnosis History: Diagnosis message 5
–
Read only
 
–
From version 03.00
 
0x10F3:012
Diagnosis History: Diagnosis message 6
–
Read only
 
–
From version 03.00
 
0x10F3:013
Diagnosis History: Diagnosis message 7
–
Read only
 
–
From version 03.00
 
0x10F3:014
Diagnosis History: Diagnosis message 8
–
Read only
 
–
From version 03.00
 
0x10F3:015
Diagnosis History: Diagnosis message 9
–
Read only
 
–
From version 03.00
 
0x10F3:016
Diagnosis History: Diagnosis message 10
–
Read only
 
–
From version 03.00
 
0x10F3:017
Diagnosis History: Diagnosis message 11
–
Read only
 
–
From version 03.00
 
0x10F3:018
Diagnosis History: Diagnosis message 12
–
Read only
 
–
From version 03.00
 
0x10F3:019
Diagnosis History: Diagnosis message 13
–
Read only
 
–
From version 03.00
 
0x10F3:020
Diagnosis History: Diagnosis message 14
–
Read only
 
–
From version 03.00
 
0x10F3:021
Diagnosis History: Diagnosis message 15
–
Read only
 
–
From version 03.00
 
0x10F3:022
Diagnosis History: Diagnosis message 16
–
Read only
 
–
From version 03.00
 
0x10F3:023
Diagnosis History: Diagnosis message 17
–
Read only
 
–
From version 03.00
 
0x10F3:024
Diagnosis History: Diagnosis message 18
–
Read only
 
–
From version 03.00
 
0x10F3:025
Diagnosis History: Diagnosis message 19
–
Read only
 
–
From version 03.00
 
0x10F3:026
Diagnosis History: Diagnosis message 20
–
Read only
 
–
From version 03.00
 
0x10F3:027
Diagnosis History: Diagnosis message 21
–
Read only
 
–
From version 03.00
 
0x10F3:028
Diagnosis History: Diagnosis message 22
–
Read only
 
–
From version 03.00
 
0x10F3:029
Diagnosis History: Diagnosis message 23
–
Read only
 
–
From version 03.00
 
0x10F3:030
Diagnosis History: Diagnosis message 24
–
Read only
 
–
From version 03.00
 
0x10F3:031
Diagnosis History: Diagnosis message 25
–
Read only
 
–
From version 03.00
 
0x10F3:032
Diagnosis History: Diagnosis message 26
–
Read only
 
–
From version 03.00
 
0x10F3:033
Diagnosis History: Diagnosis message 27
–
Read only
 
–
From version 03.00
 
0x10F3:034
Diagnosis History: Diagnosis message 28
–
Read only
 
–
From version 03.00
 
0x10F3:035
Diagnosis History: Diagnosis message 29
–
Read only
 
–
From version 03.00
 
0x10F3:036
Diagnosis History: Diagnosis message 30
–
Read only
 
–
From version 03.00
 
0x10F3:037
Diagnosis History: Diagnosis message 31
–
Read only
 
–
From version 03.00
 
0x2859:001
(P515.01)
EtherCAT monitoring: Watchdog elapsed
(EtherCAT monit.: WD elapsed)
–
From version 02.00
 
Selection of the response to the continuous interruption of communication to the EtherCAT master, e. g. by cable break or failure of the EtherCAT master.
Associated event ID:
–
33168 | 0x8190 - Network - Watchdog time-out
 
0
No response
1
Warning
2
Trouble
3
Fault
0x2859:003
(P515.03)
EtherCAT monitoring: Invalid configuration
(EtherCAT monit.: Invalid config)
–
From version 02.00
 
Selection of the response triggered by the reception of invalid configuration data.
Associated event ID:
–
33414 | 0x8286 - Network - PDO mapping error
 
0
No response
1
Warning
2
Trouble
3
Fault
0x2859:004
(P515.04)
EtherCAT monitoring: Initialisation error
(EtherCAT monit.: Init. error)
–
From version 02.00
 
Selection of the response triggered by the occurrence of an error during the initialisation of the network component.
Associated event ID:
–
33170 | 0x8192 - Network - Initialization error
 
0
No response
1
Warning
2
Trouble
3
Fault
0x2859:005
(P515.05)
EtherCAT monitoring: Invalid process data
(EtherCAT monit.: Inval. proc.data)
–
From version 02.00
 
Selection of the response triggered by the reception of invalid process data.
Associated event ID:
–
33171 | 0x8193 - Network - Invalid cyclic process data
 
0
No response
1
Warning
2
Trouble
3
Fault