Security mechanisms

Product Defense in Depth

The following image shows the defense in depth product concept. For the sake of clarity, some details have been deliberately omitted.

Product Defense in Depth

The AC and servo motors have two interfaces which are considered:

  • ETS (Electronic Name Plate)
    This interface is optional and not available for all products. No customer data is stored, only public product data is read.

  • Motor Feedback
    This interface is optional and can be implemented in different ways. No customer data is saved, only information about the motor status (with a focus on the rotor position) is read.

Both interfaces are not designed to be operated in public mains, but only on a dedicated network.

Expected Defense in Depth in the environment

The following image shows the Expected Defense in Depth in the environment of the Controller.

Expected Defense in Depth in the environment

Conduit Field:

  • The interfaces of the AC and servo motors are not suitable for operation on a security conduit. These motors are only intended for use with a suitable inverter. The field conduit must then be operated above the inverter and not at the motor interfaces.

General Environment:

  • General physical access protection must be provided for the components.

Security mechanisms:

Due to the simplicity of this approach, no security-relevant firmware functions are required.