General mapping
The Lenze Mapping Editor represents the current mapping for all visible OPC UA nodes in the middle of the screen in a mapping table. The possibility to scroll through the information model and the mapping synchronously provides a good overview which nodes are already mapped to a Data Source item.
To perform a mapping, navigate in the OPC UA information model to the Node to be mapped.
The mapping can be done by "drag & drop" of the Data Source item to the mapping table field of the desired OPC UA node.
Depending on the Data Source item following OPC UA NodeClasses are mappable. Only these nodes provide a link icon in the mapping table and the "Node Mapping Attributes".
-
Variable (DataVariable and Property)
-
Method
-
EventType-Notifier
To check the mapping, a project compile of the PLC project is necessary in the »PLC Designer«.
The following chapters describe which items are mappable and what are the constraints.
As a convenience feature the Mapping Editor is able to do an OPC UA variable node instantiation and mapping automatically. Just “drag and drop” the data source item to the OPC UA parent node in the information model. The name and type of the new OPC UA node is the same as that of the data source item.
This feature is provided for all simple variables with Built-in data types.