Lenze OPC UA Server customizing

The customizing can be used to modify the Endpoint-Description and the Certificate-Fields of the Lenze OPC UA Server to replace any Lenze-related information from the OPC UA Server. Over this way, the machine builder can do a kind of -brand-labeling- to represent the specific machine over the Lenze OPC UA Server instead of the Lenze component supplier related information.

The Lenze OPC UA Server provides a couple of parameters to modify the Endpoint Description (and Application Description) and Certificate related fields.

By default, these parameters provide Lenze-specific information, that represents the Controller Device.

Customizing Discovery Url

In IP-based networks, without a Domain Name Server, it-s not possible to resolve the hostname for addressing devices. Just IP addresses can be resolved. Due to this reason, it-s possible to adapt the Endpoint (Discovery) URL of the OPC UA Server.

Index

Sub

Name

Default

Note

0x2471

135

Endpoint IP

Bit 0 = hostname

Bit 0 = hostname

Bit 1 = IP-Engineering 1

Bit 2 = IP-Engineering 2

If the parameter is set to 2 (Bit 1) the Endpoint URL of the OPC UA Server will be IP based instead of hostname based.

If the Endpoint IP parameter is set to 2 (Bit 1), the IP address is also automatically taken over to the certificate alternative name of the OPC UA Server.

The new Endpoint URL will be applied after controller reboot.

The new certificate alternative name will be applied after certificate re-creation.

Customizing Endpoint Description

To modify the Endpoint Description related fields, following parameters can be used. [hostname] is a placeholder for the current hostname of the device. This placeholder is automatically resolved with the hostname from parameter 0x2014:001.

Index

Sub

Name

Default

Note

0x2471

131

Product Name

Lenze Controller OPC UA Server

 

0x2471

132

Product URI

urn:Lenze:Controller:OPCUAServer

 

0x2471

133

Application Name

Lenze Controller OPC UA Server@[hostname]

 

0x2471

134

Application URI

urn:[hostname]:Lenze:Controller:OPCUAServer

 

These parameters change the values of the Application Description defined in OPC UA Specification Part 4 - 7.1

Name

Type

Description

ApplicationDescription

structure

Specifies an application that is available.

applicationUri

String

The globally unique identifier for the application instance. This URI is used as ServerUri in Services if the application is a Server.

productUri

String

The globally unique identifier for the product.

applicationName

LocalizedText

A localized descriptive name for the application.

-

-

-

The Application URI should be based on the Product URI and only a device instance information should be added. Here the device specific instance information is reflected by the hostname of the controller.

In the same manner the Application Name should based on Product Name. Only the instance specific information must be added to follow the OPC UA standard accordingly.

The endpoint description related information will be applied after controller reboot

To check the endpoint related information on client side, just connect with the UA Expert and add the Server Diagnostics View. The product name can be checked in the ServerStatus-Object under the Server node.

Ein Bild, das Text enth-lt.

Automatisch generierte Beschreibung

Customizing Server Certificate

To modify the Certificate related fields, following parameters can be used.

Index

Sub

Name

Default

Note

0x2471

141

Certificate Country

DE

A certificate country code is a two-letter code.

0x2471

142

Certificate Domain Component

Lenze.com

 

0x2471

143

Certificate Locality

Aerzen

 

0x2471

144

Certificate Organization

Lenze

 

0x2471

145

Certificate Organization-Unit

Controls

 

0x2471

146

Certificate State

Niedersachsen

 

0x2471

147

Certificate IPs

 

Use a comma -,- as separator for multiple IP addresses. Blank characters are not allowed.

e.g.: -10.10.10.10,172.31.207.183-

In general, the Endpoint-related information described above are interlinked with the certificate information. For instance, the Application Name and ApplicationURI is also part of the certificate information.

The settings are applied after deleting the current server certificate and creating a new one by controller reboot.

If a new Product URI or certificate has been created, a secure connection with previously trusted certificates is no longer possible.

A self signed Certificate has to be trusted again on client side.

A new CA signed Certificate has to be created by a GDS.