A12_Configuration
This folder contains the function module L_EATP_FAST_Config , which can be used to carry out a basic configuration of the application template.
Settings for this function block can only be made before the PLC is started and not during runtime.
|
|
|
|
L_EATP_FAST_Config |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
BOOL |
- |
|
xFASTSystemInTaskMid |
eFAST SystemTaskContext |
|
- |
ENUM |
|
BOOL |
- |
|
xLogErrorTypeWarning |
|
|
|
|
|
|
|
|
|
|
|
|
|
Inputs
|
Identifier Data type |
Description of the |
|
|---|---|---|
|
xFASTSystemInTaskMidPrio BOOL |
TRUE |
The logic and infrastructure functions of the application template are calculated in the mid-task. This reduces the load on the high task. |
|
xLogErrorTypeInformation BOOL |
TRUE |
The information generated via the ErrorSet module (BF02_SetErrors) is entered in the logbook. |
|
xLogErrorTypeWarning BOOL |
TRUE |
The warnings generated via the ErrorSet module (BF02_SetErrors) are entered in the logbook. |
Outputs
|
Identifier Data type |
Description of the |
|---|---|
|
eFASTSystemTaskContext ENUM |
Display of the task in which the logic and infrastructure functions of the application template are calculated. |