A20_Visualisation

This folder contains the main visualisation L_Main , in which all visualisations of the individual machine modules are mounted.

The main visualisation consists of three areas:

Machine module list

Display of all machine modules that are available in the Machine Module Tree.

MM Addr.: Machine module address MN Name: Machine module name

ST: Machine module status (green: error-free; red: error present)

BY: Machine module status (green: ready for operation; red: not ready for operation)

CPL: Machine module coupling mode

  • "DEF": Module coupling is switched on.

  • "DIS": Module coupling is switched off. The IC module is in the "Internal Control" state.

The order in the list corresponds to the call sequence.

"Machine Module Details"

Display of detailed information on the module selected in the machine module list.

Buttons

Up/Down: Move the cursor (selection marker) in the list.

Generic visualisations