Outputs
|
Identifier Data type |
Description |
|---|---|
|
xReadyForMotion BOOL |
The axle is released and fault-free. The brake is released. A movement job can be started. |
|
xImpActive BOOL |
Pulse block active, inverter switched off |
|
xMotorMagnetised BOOL |
Motor is magnetised |
|
xVoltageEnabled BOOL |
DC link voltage present |
|
xBrakeReleaseOut BOOL |
Holding brake is activated for opening. |
|
xBrakeReleased BOOL |
Holding brake is open (brake release time has expired). |
|
xTorqueLimitsActive BOOL |
xActivateTorqueLimitNeg AND/OR xActivateTorqueLimitPos is TRUE. |
|
xSuspendFollowErrorActive BOOL |
Following error monitoring is deactivated. |
|
lrActTorque LREAL |
Current torque (gearbox output side) in [Nm] |
|
lrActualMotorCurrent LREAL |
Current motor current from 0x6078:0.
Unit: [%] |
|
lrDC_BusVoltage LREAL |
Current DC link voltage from 0x6079:0.
Unit: [V] |
|
lrThermalLoadDevice LREAL |
Device Actual utilisation from 0x2D40:4.
Unit: [%] |
|
lrThermalLoadMotor LREAL |
Motor utilisation (i²t) from 0x2D4F:0.
Unit: [%] |
|
lrActualMotorTemperature LREAL |
Actual motor temperature from 0x2D49:5.
Unit: [°C] |
|
eAxisState L_MC1P_Axis_State |
Current PLCopen status of the axis |
|
xLimitationActive BOOL |
Internal limitation of a setpoint active. (0x6041 Bit11) |
|
xLimitationSetTorque BOOL |
Torque: Target torque limited (Lenze status word bit 3) |
|
lrActTorqueScaled LREAL |
Standardised actual torque value in relation to the reference torque |
|
xCiA402ModesActive BOOL |
The drive can receive cyclical setpoints from the application. No inverter-specific function such as PLI or MOL is active that prevents cyclical setpoint specification. |
|
lr_ActSpeed_rpm LREAL |
Current speed Unit [rpm] |
|
lrSetTorque xMonitoringThermalLoadMotor LREAL |
Current target torque Unit: [Nm]
|