Inputs

Basic functions

Designator

Data type

Description

xEnable

BOOL

TRUE

The function block is activated.

FALSE

The function block is deactivated.

xEnableOperation

BOOL

TRUE

The axis is switched to the "ready for operation" state.

Controller enable is issued.

xResetError

BOOL

FALSEäTRUE

Reset axis error or software error.

xQSPApplication

BOOL

TRUE

The axis is brought to a standstill with speed control and/or held there with position control using the parameters of the QSP application.

  • The technology module remains in the "STOP" state as long as the quick stop is executed.

  • The function cannot be replaced by another function.

  • The Quick Stop (QSP) application is intended for use in the event of an error.

  • Regardless of the active setpoint, the generated stop ramp starts at the current speed.

  • The axis stops in velocity-controlled mode (CSV).

  • After the ramp is complete, the drive switches to position control (CSP).

  • The stop function is used to quickly stop the individual drive. If this drive is the master drive for one or more other drives, a different function, such as ABORT or HALT, should be used to stop the entire master drive system. Otherwise, position jumps may occur in the sequential drives when they are activated due to the control changeover.

xAbort

BOOL

FALSEäTRUE

The axis is brought to standstill using the parameters of the movement function that was interrupted. Stopping can be replaced by activating a movement function.

xJogPos

BOOL

TRUE

Traverse axis in positive direction (manual jog).

If xJogNeg is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xJogNeg

BOOL

TRUE

Traverse axis in negative direction (manual jog).

If xJogPos is also TRUE, the eErrorID output displays the "InvalidInputJogPosJogNeg" error message and the axis stops.

xHomeExecute

BOOL

FALSEäTRUE

Start homing.

The function is aborted via the xHalt input.

lrOverride

LREAL

With the lrOverride factor, the defined setpoint speed is multiplied (e.g. an override value of 0.5 generates half the setpoint speed)

  • Value range: 0 ... 1.0

  • Initial value: 1.0

Note: Acceptance of the value is carried out irrespective of the status in xContinuousUpdate.

scCtrlBasicMotion

L_TB2P_scCtrlBasicMotion

Structure input for controlling basic motion functions

scPar

L_TB2P_scPar_BasicMotionBase

The parameter structure contains the parameters of the technology module.

Axis

AXIS_REF

Reference to the axis