L_TB2P_StatusBasicMotion

 

 

 

L_TB2P_StatusBasicMotion

 

 

 

L_TB2P_scStatusBasic

Motion

–

 

scStatusBasicMotion

xFunBusy

 

–

BOOL

 

 

 

xFunDone

 

–

BOOL

 

 

 

 

xFunCommandAborted

 

–

BOOL

 

 

 

 

xHaltBusy

 

–

BOOL

 

 

 

 

xHaltDone

 

–

BOOL

 

 

 

 

eControlMode

 

–

L_MC1P_ControlMode

 

 

 

 

xHwLimitSwitchNeg

 

–

BOOL

 

 

 

 

xHwLimitSwitchPos

 

–

BOOL

 

 

 

 

xSwLimitEnabled

 

–

BOOL

 

 

 

 

xSwLimitSwitchNeg

 

–

BOOL

 

 

 

 

xSwLimitSwitchPos

 

–

BOOL

 

 

 

 

eAxisType

 

–

L_MC1P_DriveType

 

 

 

 

eAxisState

 

–

L_MC1P_AXIS_STATE

 

 

 

 

xAxisWarning

 

–

BOOL

 

 

 

 

xAxisError

 

–

BOOL

 

 

 

 

xDriveWarning

 

–

BOOL

 

 

 

 

xDriveError

 

–

BOOL

 

 

 

 

dwDriveErrorID

 

–

DWORD

 

 

 

 

xConstantVelocity

 

–

BOOL

 

 

 

 

xAccelerating

 

–

BOOL

 

 

 

 

xDecelerating

 

–

BOOL

 

 

 

 

xDirectionPositive

 

–

BOOL

 

 

 

 

xDirectionNegative

 

–

BOOL

 

 

 

 

xInPosition

 

–

BOOL

 

 

 

 

xAxisAvailable

 

–

BOOL

 

 

 

 

xStandstillSetVelocity

 

–

BOOL

 

 

 

 

xStandstillActVelocity

 

–

BOOL

 

 

 

 

 

 

 

 

Designator

Data type

Description

xFuncBusy

BOOL

TRUE

Processing of the activated function running.

The DC bus voltage is available.

xFunDone

BOOL

TRUE

Execution of the activated function completed successfully.

xFunCommandAborted

BOOL

TRUE

The function activated has been aborted by another function block.

xHaltBusy

BOOL

TRUE

The holding function is executed

xHaltDone

BOOL

TRUE

The holding function has been completed successfully.

eControlMode

L_MC1P_ControlMode

Current control mode of the axis

xHwLimitSwitchNeg

BOOL

TRUE

Negative hardware limit switch exceeded.

xHwLimitSwitchPos

BOOL

TRUE

Positive hardware limit switch exceeded.

xSwLimitEnabled

BOOL

TRUE

Monitoring of the software limit positions is activated.

xSwLimitSwitchNeg

BOOL

TRUE

Negative software limit position exceeded.

xSwLimitSwitchPos

BOOL

TRUE

Positive software limit position exceeded.

eAxisType

L_MC1P_DriveType

Connected axis type

eAxisState

L_MC1P_AXIS_STATE

Current PLCopen state of the axis

xAxisWarning

BOOL

TRUE

There is a warning in the axis data or in a connected function block.

xAxisError

BOOL

TRUE

The output is TRUE in case of:

  • Error in the axis data
  • Error of a connected function block
  • Error messages of the function block at the eErrorID output

xDriveWarning

BOOL

TRUE

There is a warning in the inverter.

xDriveError

BOOL

TRUE

There is an error in the inverter.

dwDriveErrorID

DWORD

TRUE

If xDriveError = TRUE or xDriveWarning = TRUE:

Error number of the error which has occurred in the inverter.

xConstantVelocity

BOOL

TRUE

The defined speed has been reached for the first time.

xAccelerating

BOOL

TRUE

The axis is accelerated.

(Increase in the speed value)

xDecelerating

BOOL

TRUE

The axis is decelerated or braked.

(Decrease in the speed value)

xDirectionPositive

BOOL

TRUE

The axis travels in positive direction.

xDirectionNegative

BOOL

TRUE

Axis travels in negative direction.

xInPosition

BOOL

TRUE

The target position has been reached.

xAxisAvailable

BOOL

TRUE

The axis can be used in the application, i.e. the initialization has been completed correctly.

Valid actual values and the communication with the lower-level drive are available.

xStandstillSetVelocity

BOOL

TRUE

The setpoint speed of the axis is zero.

xStandstilltActVelocity

BOOL

TRUE

The actual speed is within the defined window (Window standstill, subindex 132)