Relative positioning

Example: Relative positioning of a linear axis

Pos

Description

A

Negative hardware limit switch

B

Load (e.g. slide)

C

Positive hardware limit switch

D

Current actual position

E

Distance to be travelled (= lrPos_Dist input)

F

Target position (input current actual position + lrPos_Dist)

With relative positioning, the target position defined in the lrPos_Dist input corresponds to the distance to be travelled (F = E), meaning that the drive exactly travels the distance defined from the current actual position (D).

Prerequisite

  • The axis is enabled (xReadyForMotion = TRUE).

Execution

With a rising edge (FALSEäTRUE) at the xMoveRelExecute input, a travel to the relative target position (lrPos_Dist input) is started on the basis of the parameters for the motion profile (see below). The technology module changes to the "MOVEREL" state.

In order to reach the target position, the axis is brought to a standstill via the lrDec parameter. The axis reaches a standstill exactly in the target position.

After reaching the target position, the state changes back to STANDBY (xMoveRelExecute = FALSE).

During the travel process, the absolute target position in the lrPos_Dist input can be changed, which requires triggering the Execute input for positioning again.

Positioning can be interrupted via xAbort, xHalt or xQSPApplication. Via xFinishPositioning, positioning can be continued again and completed.

Travel diagram

No

xMoveRel

Execute

xFuncBusy

xFunDone

xInPosition

eTMState

Info

A

FALSE ä TRUE

FALSE ä TRUE

FALSE

FALSE

STANDBYW

MOVEREL

The axis starts the positioning run to the relative target position 500 units.

B

TRUE

TRUEæ FALSE

FALSE ä TRUE

FALSE ä TRUE

MOVERELW

STANDBY

As soon as the relative target position has been reached, xInPosition and xFunDone are set to TRUE.

C

FALSE ä TRUE

FALSE-

TRUEæ FALSE

TRUE

STANDBY

When xMoveRelExecute  is set = FALSE, xFunDone changes from TRUEæFALSE.

D

FALSE ä TRUE

FALSEä TRUEæ FALSE

TRUEæ FALSEä TRUE

TRUEæ FALSEä TRUE

STANDBYW

MOVERELW

STANDBY

The axis starts the positioning run to the relative target position 250 units.

After reaching the relative target position, xInPosition  and xFunDone are set to TRUE.

Parameters to be set

Further parameters for relative positioning can be found in the AXIS_REF in subindex 130 ... 137.