The operator is an extension of the IEC 61131-3 standard.
ADR yields the 32-bit address (or the 64-bit address, if possible) of its argument. You can pass this address to the manufacturer functions or assign them to a pointer in the project.
Syntax
VAR
<address name> : DWORD | LWORD | POINTER TO < basis data type> | __XWORD ;
END_VAR
<address name> := ADR( <variable name> );
FUNCTION_BLOCK FB_Adress
VAR
piAddress1: POINTER TO INT;
iVar1 : INT := 5;
lwAddress2 : LWORD;
iVar2 : INT := 10;
xwAddress3 : _XWORD;
iVar3 : INT;
END_VAR
piAddress1 := ADR(iVar1); // piNumber is assigned to address of iVar1
lwAddress2 := ADR(iVar2); // works for 64 bit run time system
xwAddress3 := ADR(iVar3); // works for 32 bit and 64 bit systems
|
Important |
|---|---|
|
Different from CoDeSys V2.3, you can use the When using function pointers, note that you can pass a function pointer to external libraries, but it is not possible to call a function pointer from within CODESYS. To enable a system call (runtime system), you must set the respective object property (Build tab) for the function object. |
|
Caution |
|---|---|
|
When you use an online change, the contents of addresses can shift. As a result, |
|
Caution |
|---|---|
|
Do not return |