SF_TP (FB)

Description of the function block
[Tip] Tip

The version of the function block as described here corresponds to the latest version of the function block in Version list of function blocks.

[Tip] Tip

SF_TP is a timer function block from the SafetyStandard library. It is an extension of TP, a standard IEC 61131-3 function block. The SF_TP function block contains both standard data types and safety-oriented data types (prefix: SAFE).

SF_TP is a timer function block that operates as a signal generator. A timer (ET) is counted up until the upper limit (PT) is reached. During counting up the signal variable (Q) is TRUE.

Figure 121. Function block: SF_TP

Function block: SF_TP

Table 102. VAR_INPUT

Name

Data Type

Initial Value

Description, parameter values

IN

BOOL

FALSE

Rising edge at IN starts the pulse generator.

PT

TIME

TIME#0ms

Time duration of pulse generator (in milliseconds)


Table 103. VAR_OUTPUT

Name

Data Type

Initial Value

Description, parameter values

Q

SAFEBOOL

FALSE

Pulse variable

TRUE while counting up, i.e. as long as ET is less than or equal to PT, otherwise FALSE.

ET

TIME

TIME#0ms

Elapsed time since starting the pulse generator (Q). When ET = PT, the value remains constant.


Figure 122. Timing diagram: SF_TP