You can run a visualization as .
The requirement for this is that the runtime has the component on the target system. Then the controller and the visualization are together on one device, whereby the visualization can be displayed and used on an integrated or connected display. When the application is downloaded, additional visualization code is downloaded to the target system.
You can start a visualization as TargetVisu on the target system without the development system running. This reduces memory usage on the target system considerably. That can be useful for smaller target systems. If the development system is also running, then the visualization is also displayed there in the visualization editor while it is running. Both display variants are the same in this case.
-
TIFRequirement: supports SysGraphicGDIPlus (standard on Windows platforms)
-
BMP -
JPG -
EMF -
GIF -
PNG
|
Tip |
|---|---|
|
In version Before that, the size for Windows devices was limited to |
The runtime on the target system is extended by the component Embedded. It does not contain any graphical libraries and therefore is useful for smaller systems.
An executable visualization visMain exists in the project.
-
Select the Visualization Manager object and click Add Object.
-
Select the TargetVisu object and specify the name
TargetVisu_A.A new object is in the device tree below the Visualization Manager object. The corresponding editor opens.
The
VISU_TASKvisualization task is added automatically below the task configuration. -
Select the
visMainvisualization in the Start visualization. -
Click Show Used Visualizations and check that the selected visualization is activated for a download to the associated device.
The visualization is configured. The settings in Scaling Options determine the window size and the scaling.
-
Start a suitable runtime system with the runtime component .
Configure the communication settings for your system.
The runtime system is running.
-
Compile, download, and start the application.
The application runs. The visualization starts automatically as . It displays the visualization data and allows user input.
An executable visualization visMain exists in the project below the application appTest.
-
Compile, download, and start the application.
The application
appTeststarts. In addition, the visualization starts as . It displays the visualization data and allows user input. -
Run the command-line command
VisualClientController.exe --application=appTest --flags=2on the development system. It is located in the installation directory of in..\GatewayPLC\.The visualization stops. The application is still in
runmode. -
Run the command-line command
VisualClientController.exe --application=appTest --flags=1.The visualization restarts.