0x2022:001
|
Device commands: Load default settings
–
Settings can only be changed if the PLC application is not in the "Running" status.
|
All parameters in the RAM memory of the controller are reset to the default setting that is stored in the controller firmware as default setting.
–
All parameter changes made by the user are lost during this process!
–
When the device command has been executed successfully, the value 0 is shown.
–
Loading parameters has a direct effect on cyclic communication: The data exchange for control is interrupted and a communication error is generated.
|
|
0
|
Off / ready
|
Only status feedback
|
|
1
|
On / start
|
Execute device command
|
|
2
|
In progress
|
Only status feedback
|
|
3
|
Action cancelled
|
|
4
|
No access
|
|
5
|
No access (Device disabled)
|
|
0x2022:039
|
Device commands: Load TA default settings
|
All controller parameters are reset to the default setting. Parameters that are declared separately in the application are set to the corresponding standard values from the technology application.
–
All parameter changes made by the user are lost during this process!
–
When the device command has been executed successfully, the value 0 is shown.
|
|
0
|
Off / ready
|
Only status feedback
|
|
1
|
On / start
|
Execute device command
|
|
2
|
In progress
|
Only status feedback
|
|
3
|
Action cancelled
|
|
4
|
No access
|
|
5
|
No access (Device disabled)
|