Behavior of the EtherCAT master
When the modular machine configuration is used, the EtherCAT master behavior differs from the behavior known so far:
–
As soon as one of the function blocks L_ETC_MMCController or L_ETC_MMCControllerBus is instanced in the PLC application, the EtherCAT master waits with booting the bus.
–
Via the function blocks L_ETC_MMCController and L_ETC_MMCControllerBus, a service has to be defined that determines the operating mode of the master.
–
For one, based on a configuration, the EtherCAT bus can be set to the "Operational" state. Furthermore, a "Second Station Address" (alias address) can be assigned to the EtherCAT slaves.
The function blocks L_ETC_MMCController and L_ETC_MMCControllerBus may only be instanced once within the PLC application.
The configuration is only checked while the EtherCAT master is booting. If slaves are removed or added during operation, respective checks have to be carried out by the PLC application.