Identification of the products
Order code structure
|
|
|
I
|
5
|
5
|
A
|
E
|
□
□
□
|
□
|
1
|
□
|
□
|
□
|
□
|
□□□□
|
|
Product type
|
Inverter
|
I
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product family
|
i500
|
|
5
|
|
|
|
|
|
|
|
|
|
|
|
|
Product
|
i550
|
|
|
5
|
|
|
|
|
|
|
|
|
|
|
|
Product generation
|
Generation 1
|
|
|
|
A
|
|
|
|
|
|
|
|
|
|
|
Generation 2
|
|
|
|
B
|
|
|
|
|
|
|
|
|
|
|
|
Mounting type
|
Control cabinet mounting
|
|
|
|
|
E
|
|
|
|
|
|
|
|
|
|
Rated power
(Examples)
|
0.25 kW
|
|
|
|
|
|
125
|
|
|
|
|
|
|
|
|
0.55 kW
|
|
|
|
|
|
155
|
|
|
|
|
|
|
|
|
|
2.2 kW
|
|
|
|
|
|
222
|
|
|
|
|
|
|
|
|
|
3.0 kW
|
|
|
|
|
|
230
|
|
|
|
|
|
|
|
|
|
15 kW
|
|
|
|
|
|
315
|
|
|
|
|
|
|
|
|
|
30 kW
|
|
|
|
|
|
330
|
|
|
|
|
|
|
|
|
|
Mains voltage and connection type
|
1/N/PE AC 120 V
|
|
|
|
|
|
|
A
|
|
|
|
|
|
|
|
1/N/PE AC 230/240 V
|
|
|
|
|
|
|
B
|
|
|
|
|
|
|
|
|
3/PE AC 230/240 V
|
|
|
|
|
|
|
C
|
|
|
|
|
|
|
|
|
1/N/PE AC 230/240 V
3/PE AC 230/240 V
|
|
|
|
|
|
|
D
|
|
|
|
|
|
|
|
|
3/PE AC 400 V
3/PE AC 480 V
|
|
|
|
|
|
|
F
|
|
|
|
|
|
|
|
|
Motor connections
|
Single axis
|
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
Integrated functional safety
|
Without functional safety
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
Basic Safety - STO
|
|
|
|
|
|
|
|
|
A
|
|
|
|
|
|
|
Degree of protection
|
IP20, coated
|
|
|
|
|
|
|
|
|
|
V
|
|
|
|
|
Interference suppression
|
Without interference suppression
|
|
|
|
|
|
|
|
|
|
|
0
|
|
|
|
Integrated RFI filter
|
|
|
|
|
|
|
|
|
|
|
1
|
|
|
|
|
Application
|
Default parameter setting: Region EU (50-Hz networks)
|
|
|
|
|
|
|
|
|
|
|
|
0
|
|
|
Default parameter setting: Region US (60-Hz networks)
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
|
|
Design types
|
Standard I/O without network
|
|
|
|
|
|
|
|
|
|
|
|
|
000S
|
|
Application I/O without network
|
|
|
|
|
|
|
|
|
|
|
|
|
001S
|
|
|
Standard I/O with CANopen
|
|
|
|
|
|
|
|
|
|
|
|
|
002S
|
|
|
Standard I/O with Modbus RTU
|
|
|
|
|
|
|
|
|
|
|
|
|
003S
|
|
|
Standard I/O with PROFIBUS
|
|
|
|
|
|
|
|
|
|
|
|
|
004S
|
|
|
Standard I/O with POWERLINK
|
|
|
|
|
|
|
|
|
|
|
|
|
012S
|
|
|
Standard I/O with EtherCAT
|
|
|
|
|
|
|
|
|
|
|
|
|
00KS
|
|
|
Standard I/O with PROFINET
|
|
|
|
|
|
|
|
|
|
|
|
|
0xLS
|
|
|
Standard I/O with EtherNet/IP
|
|
|
|
|
|
|
|
|
|
|
|
|
0xMS
|
|
|
Standard I/O with Modbus TCP
|
|
|
|
|
|
|
|
|
|
|
|
|
0xWS
|
|
|
Standard I/O with IO-Link
|
|
|
|
|
|
|
|
|
|
|
|
|
016S
|
|
Order code
|
Meaning
|
|
I55AE311F1AV1000KS
|
Inverter i550 cabinet, 11 kW, 3-phase, 400 V/480 V
STO safety function, IP20, varnished, integrated RFI filter; 50 Hz variant
Standard I/O with EtherCAT network
|