Required commissioning steps
1.
Activate motor control type: 0x2C00 (P300.00) = "Sensorless control for synchronous motors (SLSM-PSM) [8]".
2.
Automatic motor identification (energized)
–
Mandatory for this motor control mode in order to determine the equivalent circuit data and calculate the parameters for encoderless operation with HF injection.
3.
Optionally for a speed control with torque limitation in operating mode 0x6060 (P301.00) = "MS: Velocity mode [-2]":
–
Select the source in 0x2949:001 (P337.01) for the positive torque limit source and set it accordingly.
–
Select the source in 0x2949:002 (P337.02) for the negative torque limit source and set it accordingly.
4.
Optionally for a speed control with torque limitation in operating mode 0x6060 (P301.00) = "CiA: Velocity mode (vl) [2]":