Current controller (field-oriented control)
For quick commissioning, the calculations and settings are made automatically during the motor calibration.
For typical applications, a manual adaptation of the parameters of the current controller is not recommended. An incorrect setting may have a negative effect on the control. For special applications, contact the manufacturer before adapting the parameters.
Preconditions
The current controller described here is only effective in the following motor control mode:
–
Sensorless control for synchronous motors (SLSM-PSM)
The current controller parameters are calculated based on the stator resistance and leakage inductance. Thus, the following parameters must be set correctly, either via optimization or manually (according to manufacturer-data/motor data sheet):
–
0x2C01:002: Stator resistance
–
0x2C03:005 (P352.05): D-axis inductance Ld
–
0x2C03:006 (P352.06): Q-axis inductance Lq
Parameter
Motor equivalent circuit diagram data
Sensorless control for synchronous motor (SLSM-PSM)