Correction of the stator leakage inductance (Lss)

Parameter
Address
Name / setting range / [default setting]
Information
0x2C05
Reference for current grid points (x) Lss saturation characteristic
0.1 ... [5.4] ... 2500.0 A
Setting of the maximum motor current.
Serves as reference value for the scaled current data of the X axis of the saturation characteristic.
0x2C09:001
q-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %)
0 ... [100] ... 400 %
0x2C09:003
q-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %)
0 ... [100] ... 400 %
0x2C09:005
q-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %)
0 ... [100] ... 400 %
0x2C09:007
q-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %)
0 ... [100] ... 400 %
0x2C09:009
q-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %)
0 ... [100] ... 400 %
0x2C09:011
q-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %)
0 ... [100] ... 400 %
0x2C09:013
q-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %)
0 ... [100] ... 400 %
0x2C09:015
q-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %)
0 ... [100] ... 400 %
0x2C09:017
q-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %)
0 ... [100] ... 400 %