Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28A1
SSE Source SD-In
–
Safety parameter (Safety parameter list)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
16
SD-In1-A
17
SD-In1-B
18
SD-In2-A
19
SD-In2-B
0x28A2
SSE Source S-Bus
–
Safety parameter (Safety parameter list)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28A3:001
SSE: Emergency stop function
–
Safety parameter (Safety parameter list)
 
Selection of the stop function for emergency stop.
0
STO
1
SS1
0x28A4
SSE "SSE active" - Output
–
Safety parameter (Safety parameter list)
 
Selection of the safe output for the "SSE active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic