0x28A8
|
OMS Source
–
Safety parameter (Safety parameter list)
|
Selection of the trigger source for the function.
|
|
0
|
Disabled
|
|
|
1
|
SD-In1
|
|
2
|
SD-In2
|
|
13
|
S-Bus
|
|
16
|
SD-In1-A
|
|
17
|
SD-In1-B
|
|
18
|
SD-In2-A
|
|
19
|
SD-In2-B
|
|
0x28A9:001
|
OMS: Stop function
–
Safety parameter (Safety parameter list)
|
Definition of the stop function in special operation.
|
|
0
|
STO
|
|
|
1
|
SS1
|
|
0x28A9:002
|
OMS: Motion function
–
Safety parameter (Safety parameter list)
|
Definition of the motion function in special operation.
|
|
11
|
Free mode
|
|
|
0x28A9:003
|
OMS: Function at low level
–
Safety parameter (Safety parameter list)
|
Function that is executed at LOW level on the safe input with the OMS function.
 CAUTION!
According to the closed-circuit principle, no additional danger may emanate from the parameterization!
|
|
0
|
Normal operation
|
|
|
1
|
Special operation
|
|
0x28AA
|
OMS "OMS active" - Output
–
Safety parameter (Safety parameter list)
|
Selection of the safe output for the "OMS active" feedback.
|
|
0
|
Disabled
|
|
|
1
|
SD-Out1 positive logic
|
|
2
|
SD-Out1 negative logic
|