ASM field weakening controller

For a quick commissioning, the calculations and settings are made automatically during the motor calibration.
 
Preconditions
The field weakening controller is only effective in the following motor control types:
–
Servo control (SC ASM)
 
–
Sensorless vector control (SLVC)
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x29E0:001
Field weakening controller settings: Gain (ASM)
0.000 ... [0.000]* ... 2000000.000 Vs/V
* Default setting dependent on the model.
Gain factor Vp of the field weakening controller.
0x29E0:002
Field weakening controller settings: Reset time (ASM)
1.0 ... [1478.3]* ... 240000.0 ms
* Default setting dependent on the model.
Reset time Tn of the field weakening controller.
0x29E1
Field weakening controller Field limitation
5.00 ... [100.00] ... 100.00 %
–
From version 04.00
 
Field limitation of the field weakening controller.