0x28DD
|
PDSS Source S-Bus
–
Safety parameter (+Safety parameter list+)
|
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x28DE:001
|
PDSS: Permanent activation
–
Safety parameter (+Safety parameter list+)
|
Selection of how the function is activated.
Changes only possible in the +Safety parameter list+.
|
|
0
|
On demand
|
On request via defined source.
|
|
1
|
Activated
|
Permanent activation
|
|
0x28DE:002
|
PDSS: Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Definition of the lower position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:003
|
PDSS: Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Definition of the upper position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:004
|
PDSS: Lower SCS limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Lower SCS limit for PDSS.
Value less than or equal to the lower position limit deactivates the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:005
|
PDSS: Upper SCS limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Upper SCS limit for PDSS.
Value less than or equal to the upper position limit deactivates the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:006
|
PDSS: SCS from lower limit
0 ... [0] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
|
Safe creeping speed from the lower SCS limit onwards in the direction of the lower position limit.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:007
|
PDSS: SCS from upper limit
0 ... [0] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
|
Safe creeping speed from the upper SCS limit onwards in the direction of the upper position limit.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:008
|
PDSS: Maximum speed
0 ... [0] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
|
Value of the maximum permissible speed for the function.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:009
|
PDSS: Maximum deceleration lower limit
0 ... [0] ... 32000
–
Safety parameter (+Safety parameter list+)
|
Amount of the maximum deceleration in the direction of the lower position limit.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:010
|
PDSS: Maximum deceleration upper limit
0 ... [0] ... 32000
–
Safety parameter (+Safety parameter list+)
|
Amount of the maximum deceleration in the direction of the upper position limit.
Changes only possible in the +Safety parameter list+.
|
|
0x28DE:011
|
PDSS: Error response
–
Safety parameter (+Safety parameter list+)
|
Response to errors detected in the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
STO
|
|
|
1
|
SS1
|
|
2
|
SS2
|
|
0x28DE:012
|
PDSS: Currently monitored speed
–
Read only: x rpm
–
Safety parameter (+Safety parameter list+)
|
Display of the currently monitored speed.
|
|
0x28DE:013
|
PDSS: Minimum difference monitored speed
–
Read only: x rpm
–
Safety parameter (+Safety parameter list+)
|
Minimum difference between actual speed and monitored envelope curve.
|