Setting

Please note when setting the parameters:
–
The internal brake module must control the holding brake.
 
–
"Normal" must be parameterized for the brake polarity.
 
–
Other settings are not compatible with the SBC function.
 
 
The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28E5
SBC Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
0
Disabled
1
Activated
0x28E6:001
SBC: Brake mode
–
Safety parameter (+Safety parameter list+)
 
Selection whether the STO control is combined with the brake control.
Changes only possible in the +Safety parameter list+.
1
SBC without STO
2
Automatic with STO
0x28E6:002
SBC: Delay SBC
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC request and activation of the brake output.
Changes only possible in the +Safety parameter list+.
0x28E6:003
SBC: Delay STO
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC request and activation of STO in automatic mode.
Changes only possible in the +Safety parameter list+.
0x28E6:004
SBC: Brake open delay
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC deactivation and brake opening.
Changes only possible in the +Safety parameter list+.