Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28D8:001
SCA: SCA1 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the lower position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
0x28D8:002
SCA: SCA2 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D8:003
SCA: SCA3 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D8:004
SCA: SCA4 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:001
SCA: SCA1 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the upper position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
0x28D9:002
SCA: SCA2 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:003
SCA: SCA3 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:004
SCA: SCA4 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)