0x28B9:001
|
SDI: SDIpos - Source S-Bus
–
Safety parameter (+Safety parameter list+)
|
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x28B9:002
|
SDI: SDIneg - Source S-Bus
–
Safety parameter (+Safety parameter list+)
|
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x28BA:001
|
SDI: Monitoring standard operation
–
Safety parameter (+Safety parameter list+)
|
Setting of a permanent monitoring function for the direction of movement in normal operation.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Both directions enabled
|
|
|
1
|
Positive direction enabled
|
|
2
|
Negative direction enabled
|
|
0x28BA:002
|
SDI: Delay time
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
|
Safe monitored time from activation to switching on the monitoring SDIpos or SDIneg.
Changes only possible in the +Safety parameter list+.
|
|
0x28BA:003
|
SDI: Tolerance threshold
0 ... [8192] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
|
Setting of the tolerance threshold specifying by how many increments the motor may move in the direction locked by SDI.
The incremental position value is related to the motor encoder.
Changes only possible in the +Safety parameter list+.
|
|
0x28BA:004
|
SDI: Error response
–
Safety parameter (+Safety parameter list+)
|
Response when a wrong direction of movement of the motor is detected.
Changes only possible in the +Safety parameter list+.
|
|
0
|
STO
|
|
|
1
|
SS1
|
|
2
|
SS2
|
|
0x28BA:005
|
SDI: Maximum change of position
–
Read only: x incr.
–
Safety parameter (+Safety parameter list+)
|
Maximum occurred position change in the not allowed direction when SDI is active.
|