Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x289E
SOS Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
0
Disabled
1
Activated
0x289F:001
SOS: Tolerance window (Delta p=0)
0 ... [8192] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
 
If the position change is within the tolerance window, the status "
D
p = 0" is valid.
Changes only possible in the +Safety parameter list+.
0x289F:002
SOS: Restart
–
Safety parameter (+Safety parameter list+)
 
Restart behavior after the function has been canceled.
Changes only possible in the +Safety parameter list+.
0
Acknowledged restart
1
Automatic restart
0x289F:003
SOS: Maximum change of position
–
Read only: x incr.
 
–
Safety parameter (+Safety parameter list+)
 
Value of the maximum position change while SOS has been active.
The incremental position value is related to the motor encoder.