0x28C9
|
SLI Source S-Bus
–
Safety parameter (+Safety parameter list+)
|
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x28CA:001
|
SLI: Increment size standard operation
0 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
|
Number of increments for a safely limited increment in normal operation.
Changes only possible in the +Safety parameter list+.
|
|
0x28CA:002
|
SLI: Error response standard operation
–
Safety parameter (+Safety parameter list+)
|
Response when the safe increment is exceeded in normal operation.
Changes only possible in the +Safety parameter list+.
|
|
0
|
STO
|
|
|
1
|
SS1
|
|
2
|
SS2
|
|
0x28CA:004
|
SLI: Maximum change of position
–
Read only: x incr.
–
Safety parameter (+Safety parameter list+)
|
Value of the position change while SLI has been active.
The incremental position value is related to the motor encoder.
|