Short-circuit braking
The control modes for synchronous motors provide the opportunity to use "short-circuit braking" for braking.
The effect of short-circuit braking on the deceleration behaviour depends on the motor properties, the effective cable length, the load inertia and the initial speed value (starting point). Primarily, short-circuit braking serves to transform a part of the kinetic energy into heat energy which unburdens external brake assemblies and limit position dampers.
In some constellations it is not possible to decelerate the speed of a synchronous motor to zero by means of "short-circuit braking"!
Compared to the "quick stop" function, the braking effect is considerably lower.
Preconditions
If short-circuit braking shall be used as the only deceleration means, it is recommended that the feasibility is previously verified by means of tests. For this purpose, short-circuit braking can be triggered in the application via bit 6 in the Lenze control word 0x2830. The oscilloscope function of the engineering tool (e.g. »EASY Starter«) serves to record the following important parameters:
Details
The short-circuit current adjusts itself freely in accordance with the motor voltage (kE * speed) and the internal resistance of the system. Thus, it is absolutely necessary that the ampacity of the servo inverter is based on the maximum expected short-circuit current. Guide value: Imax_device (3 s) ≥ 1.5 * Imax_motor (according to data sheet / catalog) In case the assignment differs, a rating based on the currently possible parameters (max. speed, max. motor current, field weakening, etc.) is required!
The function can be used as follows:
1.
"Short-circuit braking" can be parameterised via bit 6 in the Lenze control word 0x2830 if
–
the braking energy cannot be converted into heat in a brake resistor.
–
e.g. an error has been detected in the encoder system which does not permit a braking via quick stop.
2.
"Short-circuit braking" can be parameterised as a response to minor faults.
–
Due to an encoder error, for instance, a quick stop might not be possible anymore.