0x2C01:002
|
Motor parameters: Stator resistance
0.0000 ... [13.5000] ... 125.0000 Ω
|
General motor data.
Carry out settings as specified by manufacturer data/motor data sheet.
Note!
When you enter the motor nameplate data, take into account the phase connection implemented for the motor (star or delta connection). Only enter the data applying to the connection type selected.
|
|
0x2C01:003
|
Motor parameters: Stator leakage inductance
0.000 ... [51.000] ... 500.000 mH
|
|
0x2C01:009
|
Motor parameters: Insulation class
|
Insulation class of the motor (see motor nameplate).
|
|
0
|
Y (cut-off temperature = 90 °C)
|
|
1
|
A (cut-off temperature = 105 °C)
|
|
2
|
E (cut-off temperature = 120 °C)
|
|
3
|
B (cut-off temperature = 130 °C)
|
|
4
|
F (cut-off temperature = 155 °C)
|
|
5
|
H (cut-off temperature = 180 °C)
|
|
6
|
G (cut-off temperature > 180 °C)
|
|
0x2C02:001
|
Motor parameter (ASM): Rotor resistance
0.0000 ... [0.0000] ... 214748.3647 Ω
|
Equivalent circuit data required for the motor model of the asynchronous machine.
|
|
0x2C02:002
|
Motor parameter (ASM): Mutual inductance
0.0 ... [0.0] ... 214748364.7 mH
|
|
0x2C02:003
|
Motor parameter (ASM): Magnetising current
0.00 ... [0.00] ... 500.00 A
|
|
0x2C03:001
|
Motor parameter (PSM): Back EMF constant
0.0 ... [41.8] ... 100000.0 V/1000rpm
|
Voltage induced by the motor (rotor voltage / 1000 rpm).
For permanently excited synchronous motors, the e.m.f. constant describes the r.m.s. value of the line-to-line voltage (phase voltage) induced in idle state by the motor (reference: 1000 rpm, 20 °C). Measured: Line to Line (L - L)
|
|
0x2C03:002
|
Motor parameter (PSM): Resolver pole position
-179.9 ... [-90.0] ... 179.9 °
|
Equivalent circuit data required for the motor model of the synchronous machine.
|
|
0x2C03:003
|
Motor parameter (PSM): Magnets temperature coefficient (kTN)
-1.000 ... [-0.110] ... 0.000 %/°C
|
|
0x2C03:004
|
Motor parameter (PSM): Encoder pole position
-179.9 ... [0.0] ... 179.9 °
|