Process input data (CiA 402 objects)

Parameter
Address
Name / setting range / [default setting]
Information
0x6060
CiA: Operation mode
CiA: Operation mode
-13
MS: Manual jog open loop (MOL)
Manufacturer-specific manual control
-12
MS: Pole position identification (PPI)
Manufacturer-specific pole position identification (PLI)
0
No selection
No selection
2
CiA: Velocity mode (vl)
8
CiA: Cyclic sync position (csp)
9
CiA: Cyclic sync velocity mode (csv)
10
CiA: Cyclic sync torque mode (cst)
0x6071
Set torque
-3276.8 ... [0.0] ... 3276.7 %