Monitoring the speed deviation

Monitoring of the speed deviation shall only be used in the following control modes:
–
Servo control for synchronous motor (SM)
 
–
Servo control for asynchronous motor (ASM)
 
Monitoring of the speed deviation is effective in the operating modes with speed controller. It monitors the system deviation at the input of the speed controller (see blue arrow):
The error response set in 0x2D51:003 is executed if
1.
the set tolerance of the speed deviation is 0x2D51:001 exceeded and
 
2.
the exceedance lasts at least as long as set in 0x2D51:002.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2D51:001
Position error/speed error - monitoring: Speed error - error threshold
1 ... [50] ... 2147483647 rpm
Setting of the error threshold for speed error monitoring.
0x2D51:002
Position error/speed error - monitoring: Speed error - min. time for error
0 ... [0] ... 50 ms
Setting of the minimum time a speed error must be pending until an error/warning message is triggered.
0x2D51:003
Position error/speed error - monitoring: Speed error - error response
Setting of the error response of speed error monitoring.
0
No response
1
Fault > CiA402
2
Warning