Commissioning steps
Only a few steps are required to commission an inverter.
Preconditions:
–
The complete drive system is mounted and correctly wired.
–
A project and a PLC program are created in the "PLC Designer".
–
All components are supplied with voltage.
–
EtherCAT is configured and at least in "Pre-Operational" state.
–
The »PLC Designer« is connected "online" to the inverter.
Main commissioning steps
How to quickly commission the inverter:
1.
Select connected motor from the motor catalog.
Motor data
Motor data 2.
Set control mode.
Configuring the motor control
Configuring the motor control 3.
Configure feedback system:
a.
Feedback system for motor control.
Configure feedback system for motor control
Configure feedback system for motor control b.
Feedback system for Extended Safety.
4.
Check wiring (cable check).
Cable check
Cable check If no error has occurred, the system can be tested.
5.
Log in to the Lenze controller with Online → Log in.
The EtherCAT configuration and the PLC program are loaded into the controller. Any existing data will be overwritten.
The EtherCAT configuration and the PLC program are loaded into the controller. Any existing data will be overwritten.
6.
Start PLC program with <F5> or the Debug → Start menu command.
7.
Execute manual jog:
a.
Select the inverter in the device tree.
b.
Disable inverter if necessary.
c.
Select the "Manual jog" command in the context menu of the inverter.
The dialog box for manual control appears.
d.
Set parameters.
e.
Start manual jog with the "Start" button.
The "Stop" button can be used to stop manual jog at any time.
The "Stop" button can be used to stop manual jog at any time.
8.
Optimize control.
Options for optimizing the control loops
Options for optimizing the control loops Commissioning is completed.