Important notes
DANGER!Incorrect wiring can cause unexpected states during the commissioning phase.
Possible consequences: death, severe injuries or damage to property
Ensure the following before switching on the mains voltage:
▶
Wiring must be complete and correct.
▶
Wiring must be free of short circuits and earth faults.
▶
The motor circuit configuration (star/delta) must be adapted to the inverter output voltage.
▶
The motor must be connected in-phase (direction of rotation).
▶
The "emergency switching off" function of the overall system must operate correctly.
DANGER!Incorrect settings during commissioning may cause unexpected and dangerous motor and system movements.
Possible consequences: death, severe injuries or damage to property
▶
Clear hazardous area.
▶
Observe safety instructions and safety clearances.
NOTICE
The set mains voltage is lower than the actual mains voltage.
Possible consequences: Destruction of a connected brake resistor.
Due to the mains voltage being set too low, the voltage threshold for braking operation ("brake chopper threshold") is within the permissible range of the DC-bus voltage. As a result, the brake chopper is continuously in operation and the brake resistor is thermally overloaded.
▶
First switch on the 24 V supply and check whether the setting of the mains voltage corresponds to the supply network:
0x2540:001 (Rated mains voltage).
0x2540:001 (Rated mains voltage).▶
If it is ensured that the mains voltage is set correctly, the mains voltage can be switched on.