Motor-encoder combinations

The achievable risk reductions (PL/SIL) also depend on the safety function used.
Match the values specified here with the values for the safety functions:
 
 
 
Also observe the supplied documentation of the encoder manufacturer.
 
 
 
Permissible motor-encoder combinations for safe speed and position monitoring
 
Synchronous servo motors
Synchronous servo motor
Safety-rated encoder
Type
Encoder type
Encoder product code
Max. Speed
[rpm]
Risk reduction
MCS 06 ... 19
MDXKS 56 / 71
SinCos absolute value, single-turn
AS1024−8V−K2
±
16000
PL d / SIL 2
SinCos absolute value, multi-turn
AM1024−8V−K2
MCS 06 ... 19
m850S120 ... m850S190
SinCos absolute value, multi-turn
AM128−8V−K2
HIPERFACE DSL® (OCT)
AM20-8V-D2
±
15000
MCS 06 ... 19
MDXKS 56 / 71
m850S120 ... m850S190
Resolver
RV03
±
10000/number of pole pairs
PL e / SIL 3
 
Asynchronous servo motors
Asynchronous servo motor
Safety-rated encoder
Type
Encoder type
Encoder product code
Max. Speed
[rpm]
Risk reduction
MCA 10 ... 26
MQA 20 ... 26
SinCos incremental
IG1024-5V-V3
±
16000
PL e / SIL 3
MCA 10 ... 26
MQA 20 ... 26
Resolver
RV03
±
10000/number of pole pairs
PL e / SIL 3
 
Three-phase AC motors
Three-phase AC motor
Safety-rated encoder
Type
Encoder type
Encoder product code
Max. Speed
[rpm]
Risk reduction
MDxMA063 ... MDxMA225
MHxMA063 ... MHxMA225
MFxMA063 ... MFxMA132
m550P080 ... m550P225
SinCos incremental
IG2048-5V-V2
IG1024-5V-V2
±
16000
PL d / SIL 2
IG2048-5V-V3
PL e / SIL 3