Motor diagnostics

The following parameters supply some information about the current operating status of the motor.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2832
Identification status
–
Read only
 
Display of the status for the automatic identification of the motor parameters.
Bit  0
Identification enabled
Parameters for interaction with engineering tools.
Bit  1
Identification active
Bit  2
Identification completed
Bit  3
Identification failed
0x2D82
Motor actual voltage (Veff)
–
Read only: x.x V
 
Display of the current motor voltage.
0x2D83:001
Motor-Phasenströme: Zero system current
–
Read only: x.xx A
 
Display of the zero current.
0x2D83:002
Motor-Phasenströme: Phase U current
–
Read only: x.xx A
 
Display of the current of phase U.
0x2D83:003
Motor-Phasenströme: Phase V current
–
Read only: x.xx A
 
Display of the current of phase V.
0x2D83:004
Motor-Phasenströme: Phase W current
–
Read only: x.xx A
 
Display of the current of phase W.
0x2D8A
Actual speed error
–
Read only: x rpm
 
Display of the speed error.
0x6404
Motor manufacturer
["Lenze"]
Setting of the motor manufacturer.