Position control
Position control
Similar to the standard CiA 402 functionality, the scaling of the position within the "CiA 402 advanced" technology application is represented in increments or motor revolutions, i. e. the kinematics of the technology application is calculated in the higher-level controller. In the technology application, both the motor encoder and the load encoder refer to increments. If the position control loop is closed with the application encoder in the technology application, the corresponding correcting variable must refer to the resolution of the motor encoder. This conversion factor between motor encoder and load encoder must be set in the gearbox factor parameters (denominator and numerator). The resolution of the position encoder in the corresponding CiA object (standard = 16 bits / rev) must be set as a feed constant of the position encoder.
For settings, see:
Kinematic settings
Kinematic settings Example of a linear application encoder