Event ID overview

The following table contains the most important event IDs of the device in ascending order.
–
Clicking the event ID shows you a detailed description of the event.
 
–
If the device displays an "internal event" that is not listed here, restart the device. If the event persists, make a note of the event ID and contact the manufacturer.
 
 
Event ID
Event
Severity
Configurable in
0
No error
Information
-
Short circuit or earth leakage at the motor end
Fault
-
Short circuit at the motor end
Fault
-
Motor utilization too high (i²xt)
Fehler > CiA402
0x2D50:001
Trouble - utilization of the power section (ixt) too high
Fault
-
Warning - Utilization of the power section (ixt) too high
Warning
-
Fault - Device utilization (ixt) too high
Fault
-
Warning - Device utilization (ixt) too high
Warning
-
Ultimate motor current reached
Fault > CiA402
0x2D46:002
Parameterized max. motor current > max. device current
Warning
-
Clamp is active
Warning
-
Clamp responded too often
Fault
-
Warning - device utilization (ixt) too high
Warning
-
Trouble - Device utilization (ixt) too high
Fault
-
Mains failure
Fault
-
Fault - DC bus overvoltage
Fault
-
Fault - DC bus undervoltage
Trouble
-
Fault - Power unit overtemperature
Fault
-
Fault - Heat sink temperature sensor
Fault
-
Heat sink fan warning
Warning
-
Thermal overload of control unit
Information
-
Motor overtemperature
Fault > CiA402
0x2D49:002
Fault - Motor temperature sensor
Fault > CiA402
0x2D49:002
Error - Motor temperature monitoring (PTC)
Fault > CiA402
0x2D48:002
Motor overtemperature (load encoder/master encoder)
Fault > CiA402
0x2D49:002
Motor temperature sensor error (load encoder/master encoder)
Fault > CiA402
0x2D49:002
External supply voltage critical
Warning
-
Internal error
Warning
-
Warning - Internal fan
Warning
-
Incorrect parameter set download
Warning
-
Parameter error in object
Warning
-
Fault - Analog input 1
No response
0x2636:010
Fault - Pole position identification
Fault
-
Fault - Motor feedback
Fault > CiA402
0x2C45
Error - Load encoder/master encoder
Fault > CiA402
Motor encoder - Communication error
Fault > CiA402
0x2C41:004
Motor encoder - wrong absolute value because motor speed is too high
Fault > CiA402
0x2C41:004
Load encoder/master encoder - Communication error
Fault > CiA402
0x2C51:004
Load encoder/master encoder - wrong absolute value because motor speed is too high
Fault > CiA402
0x2C51:004
Fatal internal error
Fault
-
Fatal internal communication error
Fault
-
Fault - Motor holding brake
-
Fatal internal error - task overflow
Fault
-
PPI - Motor movement too large
Fault > CiA402
0x2C60
Safe torque off (STO) activated
Warning
-
Motor overspeed
Fault > CiA402
0x2D44:002
Not permitted during identification or in test mode
Warning
-
Not permitted during identification
Warning
-
Motor phase missing
No response
0x2D45:001
0x2D45:004
Motor phase failure phase U
No response
0x2D45:001
0x2D45:004
Motor phase failure phase V
No response
0x2D45:001
0x2D45:004
Motor phase failure phase W
No response
0x2D45:001
0x2D45:004
No resolver connected - command cannot be executed
Warning
-
Speed too low - command cannot be executed
Warning
-
No resolver as motor encoder connected - command cannot be executed
Warning
-
Time-out during resolver identification
Warning
-
Numeric problem during resolver identification
Warning
-
Inverter error too large
Warning
-
Identification aborted
Fault > CiA402
0x2C60
Not permitted in state 'operation enabled' or 'quick stop active'
Warning
-
No HIPERFACE® absolute value encoder as motor encoder connected - command cannot be executed
Warning
-
Connected HIPERFACE® motor encoder is not supported
Fault > CiA402
0x2C41:004
Connected HIPERFACE® motor encoder is not supported - command cannot be executed
Warning
-
Communication time-out in manual control mode
Fault
-
Motor parameter identification fault
Fault
-
Connected HIPERFACE® load encoder/master encoder is not supported
Fault > CiA402
0x2C51:004
Connected HIPERFACE® load encoder/master encoder is not supported - command cannot be executed
Warning
-
No resolver as load encoder/master encoder connected - command cannot be executed
Warning
-
No HIPERFACE® absolute value encoder as load encoder/master encoder connected - command cannot be executed
Warning
-
FIQ runtime error
Fault
-
Brand protection - check failed
Warning
-
Time-out holding brake feedforward control
Fault
-
Velocity error
Fault
-
Position error
Fault
-
Cable check - Motor movement too large
Fault
-
Cable check - Wrong motor angle detected
Fault
-
Warning - Brake resistor overload
Warning
-
Error - Brake transistor
Fault
-
Error - Charging circuit
Fault
-
Mains phase failure
Fault
-
General error (see manual)
Fault
-
Internal communication to PLC failed
Fault
-
Initialization - Parameter value could not be written
Information
-
Load default setting - Parameter value could not be written
Warning
-
Parameters - Initialization failed
Warning
-
Parameters - Loading default values failed
Warning
-
Parameters - Loading TA default values failed
Warning
-
Opening the parameter description failed
Fault
-
Opening the parameter set failed
Fault
-
Logbook: Corrupt restore data
Information
-
Logbook cleared
Information
-
Logbook: Timeout restoring data
Information
-
Logbook: Error restoring data
Information
-
First boot with this firmware version
Information
-
Logbook was restored.
Information
-
Logbook: Error reading persistent data.
Information
-
The chronology of the logbook is not consistent
Information
-
CmpLenzeErrorManagementAccess loaded without errors
Information
-
Test-Mode - More Application Credit required, application is starting delayed
Warning
-
Application-Credit - Invalid license data
Warning
-
Application-Credit - License data missing
Warning
-
Boot application - More Application Credit required
Warning
-
Application was downloaded.
Information
-
Internal error - AIS
Warning
-
Internal error - AIE
Warning
-
Internal error - Button S82
Warning
-
SD-Inx/CLx - Error
Warning
-
Internal switch-off path - Error
Warning
-
Internal switch-off path - Test pulse error
Warning
-
Reference voltage error
Warning
-
6 V voltage error
Warning
-
5 V voltage error
Warning
-
3.3 V voltage error
Warning
-
Internal error - STO activated
Warning
-
Communication error - Basic device
Warning
-
Synchronization error - Basic device
Information
-
F-parameter error
Information
-
F_Dest_Add unequal F-address
Information
-
F_Dest_Add = 0 or FFFFhex
Information
-
F_Source_Add = 0 or FFFFhex
Information
-
F_SIL exceeds technical SIL
Information
-
F_CRC_Length error
Information
-
Wrong F-parameter version
Information
-
New safety parameter set deleted
Information
-
New safety parameter set loaded
Information
-
Memory module - Access error
Warning
-
Different safety parameter sets
Warning
-
Extended Safety - No safety parameter set
Warning
-
Extended Safety - Safety parameter set defect
Warning
-
Safety parameter set - Plausibility error
Warning
-
Safety parameter set - Communication error
Warning
-
Different safety addresses detected
Warning
-
SSM - Wrong PDO version
Warning
-
PROFIsafe passivated
Information
-
PROFIsafe has left data exchange
Information
-
PROFIsafe - CRC1 error
Information
-
FSoE - Unexpected command
Information
-
FSoE - Unknown command
Information
-
FSoE - Invalid connection ID
Information
-
FSoE - CRC error
Information
-
FSoE - Watchdog expired
Information
-
FSoE - Invalid communication parameter data
Information
-
FSoE - Invalid application parameter length
Information
-
FSoE - Invalid application parameter data
Information
-
FSoE - Passivated
Information
-
FSoE - Invalid slave address
Information
-
FSoE - Invalid communication parameter length
Information
-
FSoE - Data exchange left
Information
-
Discrepancy check or function check error - SD-In1
Warning
-
Discrepancy check or function check error - SD-In2
Warning
-
Discrepancy check or function check error - SD-In3
Warning
-
Discrepancy check or function check error - SD-In4
Warning
-
Disabled SD-In2 = HIGH
Warning
-
Disabled SD-In3 = HIGH
Warning
-
Disabled SD-In4 = HIGH
Warning
-
SD-Out1 - Channel A remains stuck at HIGH
Warning
-
SD-Out1 - Channel A remains stuck at LOW
Warning
-
SD-Out1 - Channel B remains stuck at HIGH
Warning
-
SD-Out1 - Channel B remains stuck at LOW
Warning
-
SD-In1 - Channel A remains stuck at HIGH
Warning
-
SD-In1 - Channel B remains stuck at HIGH
Warning
-
SD-In2 - Channel A remains stuck at HIGH
Warning
-
SD-In2 - Channel B remains stuck at HIGH
Warning
-
SD-In3 - Channel A remains stuck at HIGH
Warning
-
SD-In3 - Channel B remains stuck at HIGH
Warning
-
SD-In4 - Channel A remains stuck at HIGH
Warning
-
SD-In4 - Channel B remains stuck at HIGH
Warning
-
CLA/CLB - Short circuit
Warning
-
SS1/SS2 - Stop time exceeded
Warning
-
SLS1 - Nlim1 exceeded
Warning
-
SLS2 - Nlim2 exceeded
Warning
-
SLS3 - Nlim3 exceeded
Warning
-
SLS4 - Nlim4 exceeded
Warning
-
SLS/SMS - Error stop not executed
Warning
-
SDIpos - Wrong direction
Warning
-
SDIneg - Wrong direction
Warning
-
SMS - Nmax exceeded
Warning
-
SOS - Tolerance limit exceeded
Warning
-
No feedback system configured
Warning
-
CAS - Round trip time exceeded
Warning
-
CAS - Hardware or discrepancy error
Warning
-
SS1/SS2 - Speed ramp exceeded
Warning
-
SLI - Safely limited increment exceeded
Warning
-
SLP1 - Position limits exceeded
Warning
-
SLP2 - Position limits exceeded
Warning
-
SLP3 - Position limits exceeded
Warning
-
SLP4 - Position limits exceeded
Warning
-
SLP - No home position
Warning
-
PDSS - Velocity exceeded
Warning
-
PDSS - Creep velocity SCS exceeded
Warning
-
PDSS - No diagnostic mark detected
Warning
-
PDSS - Diagnostic mark detected at invalid position
Warning
-
SHom - Time-out
Warning
-
SHom - Home position deleted
Information
-
SHom - Maximum slip value exceeded
Warning
-
SHom - Tolerance of start position exceeded
Warning
-
SHom - Tolerance of position comparison exceeded
Warning
-
SSM - Invalid safe velocity
Warning
-
SSM - Encoder error
Warning
-
SSM - Resolver error
Warning
-
SSM - Error in standard device data
Warning
-
SSM - Speed deviation too high
Warning
-
SSM - Synchronization error
Warning
-
Modulo axis is required
Fault
-
Start position outside cycle length
Fault
-
Different cycle lengths
Fault
-
Invalid direction of rotation
Fault
-
Mark stack - Limit reached
Fault
-
Number of virtual marks exceeded
Fault
-
Invalid synchronization parameters
Fault
-
Invalid parameter setting for jogging
Fault
-
Invalid deceleration ramp for stop function (lrStopDec <= 0)
Fault
-
Invalid diameter
Fault
-
Torque follower not cannot be activated
Fault
-
Speed follower cannot be activated
Fault
-
Invalid AxisRef connected to function
Fault
-
Motor parameters could not be read
Fault
-
Lower speed limit parameter is not mapped
Fault
-
Upper speed limit parameter is not mapped
Fault
-
Torque setpoint parameter is not mapped
Fault
-
Dancer position outside the defined range
Fault
-
Dancer limits are invalid
Fault
-
Invalid parameter setting for clutch
Fault
-
TM was not called cyclic
Fault
-
Invalid number of cam points
Fault
-
Clutching not possible (master axis is moving)
Fault
-
Invalid parameter setting of product length
Fault
-
Position of the touch probe sensor unknown
Fault
-
Gap occurred in the slave axis
Fault
-
Gap occurred in the master axis
Fault
-
Internal error
Fault
-
Invalid parameter setting of synchronous phase
Fault
-
Invalid parameter setting of the cross cutter for cutting operation
Fault
-
Invalid parameter setting of cutting length
Fault
-
Slave axis outside parking position
Fault
-
Master axis changes the direction of rotation
Fault
-
Internal - Invalid cam selected
Fault
-
Selected axis is not supported
Fault
-
Axis is not supported
Fault
-
Invalid parameter setting of profile
Fault
-
Axis enabled is required
Fault
-
Correction window out of cycle length measuring system
Fault
-
Correction value larger than correction window
Fault
-
Dancer limits not teached
Fault
-
Position of the slave axis is greater than the upper limit set
Fault
-
Position of the slave axis is smaller than the lower limit set
Fault
-
Target position is greater than the upper limit set
Fault
-
Invalid mark position
Fault
-
Invalid positioning
Fault
-
TM not called in cyclic motion task
Fault
-
Invalid parameters of traversing profile
Fault
-
Invalid coil parameters
Fault
-
Traversing angular shift limit reached
Fault
-
DC bus undervoltage
Fault
-
Coupling mode supports modulo axes only
Fault
-
X axis TM error
Fault
-
Y axis TM error
Fault
-
Diameter calculation failed
Fault
-
Actual dancer position greater than maximum dancer position
Fault
-
Parameter lrIdentDiamMaxDancerPos is invalid
Fault
-
Value for stored material in dancer is invalid (=<0)
Fault
-
Loading the diameter during identification is not allowed
Fault
-
Invalid master axis connected
Fault
-
Inversion of gearfactor not allowed. Velocity out of tolerance.
Fault
-
AC Drive Profile - Invalid parameter configuration
Fault
-
Velocity high limit is lower than velocity low limit
Fault
-
Selected set value mode is not supported
Fault
-
Invalid delay time for PT1 filter
Fault
-
Invalid mode for curve function
Fault
-
Invalid compare mode
Fault
-
Invalid mode ConvAxisV
Fault
-
Process controller - Invalid delay time
Fault
-
Process controller - Invalid rate time
Fault
-
Process controller - Invalid reset time
Fault
-
Invalid mode for signal delay
Fault
-
FrictComp - Aborted by restarting identification
Fault
-
FrictComp - Aborted by disabling follower
Fault
-
FrictComp - Max. velocity could not be reached
Fault
-
FrictComp - Acceleration too high
Fault
-
Min. diameter greater than max. diameter
Fault
-
IdentMInertia - Max. speed or max. torque too high
Fault
-
Aborted by restarting ident identification - IdentMInertia
Fault
-
IdentMInertia - Aborted by disabling follower
Fault
-
IdentMInertia - Aborted by other function
Fault
-
IdentMInertia - Max velocity not reached
Fault
-
IdentMInertia - Torque not reached
Fault
-
Mark register - Max. number of TP exceeded
Fault
-
Identification mode not supported
Fault
-
Motor rated speed =0
Fault
-
Motor moment of inertia = 0
Fault
-
Invalid start mode
Fault
-
Invalid natural frequency
Fault
-
Invalid amplitude ratio
Fault
-
Invalid compensation method
Fault
-
Compensation method cannot be changed
Fault
-
SDO access - General error
Fault
-
SDO access - Invalid index
Fault
-
SDO access - Invalid offset
Fault
-
SDO access - Invalid length
Fault
-
SDO access- Invalid data
Fault
-
SDO access - Not ready
Fault
-
SDO access - Master is busy
Fault
-
SDO access - No memory
Fault
-
SDO access - Invalid state
Fault
-
SDO access - Invalid status
Fault
-
SDO access - Time-out
Fault
-
SDO access - Invalid mailbox commands in current slave state
Fault
-
SDO access - Cable not connected to the controller
Fault
-
SDO access - All channels for SDO request busy
Fault
-
SDO - AbortCode 0x05030000 'Toggle bit not alternated'
Fault
-
SDO - AbortCode 0x05040000 'SDO protocol time-out'
Fault
-
SDO - AbortCode 0x05040001 'Client/server command specifier not valid or unknown'
Fault
-
SDO - AbortCode 0x05040002 'Invalid block size (block mode only)'
Fault
-
SDO - AbortCode 0x05040003 'Invalid sequence number (block mode only)'
Fault
-
SDO - AbortCode 0x05040004 'CRC error (block mode only)'
Fault
-
SDO - AbortCode 0x05040005 'Out of memory'
Fault
-
SDO - AbortCode 0x06010000 'Unsupported access to an object'
Fault
-
SDO - AbortCode 0x06010001 'Attempt to read a write only object'
Fault
-
SDO - AbortCode 0x06010002 'Attempt to write a read only object'
Fault
-
SDO - AbortCode 0x06020000 'Object does not exist in the object dictionary'
Fault
-
SDO - AbortCode 0x06040041 'Object cannot be mapped to the PDO'
Fault
-
SDO - AbortCode 0x06040042 'Number and length of objects to be mapped exceed PDO length'
Fault
-
SDO - AbortCode 0x06040043 'General parameter incompatibility'
Fault
-
SDO - AbortCode 0x06040047 'General internal incompatibility in the device'
Fault
-
SDO - AbortCode 0x06060000 'Access failed due to an hardware error'
Fault
-
SDO - AbortCode 0x06070010 'Data type or length of service parameters do not match'
Fault
-
SDO - AbortCode 0x06070012 'Data type does not match, service parameter too high'
Fault
-
SDO - AbortCode 0x06070013 'Data type does not match, service parameter too low'
Fault
-
SDO - AbortCode 0x06090011 'Subindex does not exist'
Fault
-
SDO - AbortCode 0x06090030 'Write access - Parameter value exceeds limits'
Fault
-
SDO - AbortCode 0x06090031 'Write access - Parameter value too high'
Fault
-
SDO - AbortCode 0x06090032 'Write access - Parameter value too low'
Fault
-
SDO - AbortCode 0x06090036 'Maximum value less than minimum value'
Fault
-
SDO - AbortCode 0x08000000 'General error'
Fault
-
SDO - AbortCode 0x08000020 'Data cannot be transferred to the application/stored in the application'
Fault
-
SDO - AbortCode 0x08000021 'Local control - 'Data cannot be transferred to the application/stored in the application'
Fault
-
SDO - AbortCode 0x08000022 Actual device state - Data cannot be transferred to the application/stored in the application'
Fault
-
SDO - AbortCode 0x08000023 'Object dictionary - Dynamic generation fails or object dictionary is missing'
Fault
-
SDO - AbortCode 0x 'Unknown abort code'
Fault
-
Invalid AxisRef
Fault
-
Input "parameter" not used
Fault
-
Requested parameter does not exist
Fault
-
Invalid state of the axis
Fault
-
Parameter number does not correspond to a Boolean parameter
Fault
-
Positive SW limit exceeded
Fault
-
Negative SW limit exceeded
Fault
-
Invalid input for source of type MC_Source
Fault
-
No setpoints generated in current PLC cycle
Fault
-
Controller disabled during operation
Fault
-
Motion prohibited by axis state
Fault
-
Positive SW limit reached
Fault
-
Negative SW limit reached
Fault
-
Touch probe - No valid source
Fault
-
Touch probe - No valid number
Fault
-
Touch Probe - Channel is already in use
Fault
-
Touch Probe - Selection not supported
Fault
-
No Touch Probe active
Fault
-
Input for external TP configuration not connected
Fault
-
Invalid acceleration
Fault
-
Invalid deceleration
Fault
-
Invalid velocity
Fault
-
Arithmetic error in profile calculation
Fault
-
Movement cannot be executed with the specified parameters
Fault
-
Velocity - Specified value exceeds parameterized maximum value
Fault
-
Acceleration - Specified value exceeds parameterized maximum value
Fault
-
Jerk - Specified value exceeds parameterized maximum value
Fault
-
Target position outside SW limits
Fault
-
MoveAbsolute - Invalid acceleration
Fault
-
MoveAbsolute - Invalid deceleration
Fault
-
MoveAbsolute - Invalid velocity
Fault
-
MoveAbsolute - Arithmetic error in profile calculation
Fault
-
MoveAbsolute - Movement cannot be executed with the specified parameters
Fault
-
MoveAbsolute - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveAbsolute - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveAbsolute - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveAbsolute - Target position outside SW limits
Fault
-
MoveAdditive - Invalid acceleration
Fault
-
MoveAdditive - Invalid deceleration
Fault
-
MoveAdditive - Invalid velocity
Fault
-
MoveAdditive - Arithmetic error in profile calculation
Fault
-
MoveAdditive - Movement cannot be executed with the specified parameters
Fault
-
MoveAdditive - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveAdditive - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveAdditive - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveAdditive - Target position outside the SW limit
Fault
-
MoveContinuousAbsolute -
Fault
-
MoveContinuousAbsolute - Invalid deceleration
Fault
-
MoveContinuousAbsolute - Invalid velocity
Fault
-
MoveContinuousAbsolute - Arithmetic error in profile calculation
Fault
-
MoveContinuousAbsolute - Movement cannot be executed with the specified parameters
Fault
-
MoveContinuousAbsolute - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousAbsolute - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousAbsolute - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousAbsolute - Target position outside SW limits
Fault
-
MoveContinuousRelative - Invalid acceleration
Fault
-
MoveContinuousRelative - Invalid deceleration
Fault
-
MoveContinuousRelative - Invalid velocity
Fault
-
MoveContinuousRelative - Arithmetic error in profile calculation
Fault
-
MoveContinuousRelative - Movement cannot be executed with the specified parameters
Fault
-
MoveContinuousRelative - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousRelative - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousRelative - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveContinuousRelative - Target position outside SW limits
Fault
-
MoveRelative - Invalid acceleration
Fault
-
MoveRelative - Invalid deceleration
Fault
-
MoveRelative - Invalid velocity
Fault
-
MoveRelative - Arithmetic error in profile calculation
Fault
-
MoveRelative - Movement cannot be executed with the specified parameters
Fault
-
MoveRelative - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveRelative - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveRelative - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveRelative - Target position outside SW limits
Fault
-
MoveSuperImposed - Invalid acceleration
Fault
-
MoveSuperImposed - Invalid deceleration
Fault
-
MoveSuperImposed - Invalid velocity
Fault
-
MoveSuperImposed - Arithmetic error in profile calculation
Fault
-
MoveSuperImposed - Movement cannot be executed with the specified parameters
Fault
-
MoveSuperImposed - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveSuperImposed - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveSuperImposed - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveSuperImposed - Target position outside SW limits
Fault
-
MoveVelocity - Invalid acceleration
Fault
-
MoveVelocity - Invalid deceleration
Fault
-
MoveVelocity - Invalid velocity
Fault
-
MoveVelocity - Arithmetic error in profile calculation
Fault
-
MoveVelocity - Movement cannot be executed with the specified parameters
Fault
-
MoveVelocity - Velocity - Specified value exceeds parameterized maximum value
Fault
-
MoveVelocity - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
MoveVelocity - Jerk - Specified value exceeds parameterized maximum value
Fault
-
MoveVelocity - Target position outside SW limits
Fault
-
Halt - Invalid deceleration
Fault
-
Halt - Arithmetic error in profile calculation
Fault
-
Halt - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
Halt - Jerk - Specified value exceeds parameterized maximum value
Fault
-
Stop - Invalid deceleration
Fault
-
Stop - Arithmetic error in profile calculation
Fault
-
Stop - Acceleration - Specified value exceeds parameterized maximum value
Fault
-
Stop - Jerk - Specified value exceeds parameterized maximum value
Fault
-
Invalid direction specified
Fault
-
Invalid buffer mode specified
Fault
-
Requested direction not enabled
Fault
-
Function cannot be executed due to axis status
Fault
-
Invalid override value
Fault
-
Concurrent MC_Power for one axis
Fault
-
Concurrent SetQuickstop for one axis
Fault
-
Cyclic PDO interface of drive disabled (0x2824)
Fault
-
Positive HW limit exceeded
Fault
-
Negative HW limit exceeded
Fault
-
Following error - Warning level exceeded
Fault
-
Following error - Error level exceeded
Fault
-
Communication error to controlled drive
Fault
-
Initialization error of the axis data
Fault
-
Communication time-out to controlled drive
Fault
-
EtherCAT could not be restarted
Fault
-
Not ready for re-initialization
Fault
-
Error during initialization
Fault
-
Axis could not be switched on
Fault
-
Drive error
Fault
-
Homing - No homing parameters defined
Fault
-
Homing - Mode not supported by axis
Fault
-
Homing - Mode unknown
Fault
-
Homing - No external touch probe configuration
Fault
-
Homing - Invalid touch probe configuration
Fault
-
Homing - Error writing parameters to the drive
Fault
-
Homing - Error in drive during homing
Fault
-
Homing - Arithmetic error in profile calculation
Fault
-
Homing - Torque limits not mapped
Fault
-
Homing - Invalid velocity or acceleration
Fault
-
Reset of drive error failed
Fault
-
Position drift during brake test
Fault
-
Invalid brake mode
Fault
-
Torque pre-control - Time-out
Fault
-
Invalid brake state
Fault
-
Fast_IO_OUT - Invalid output selected
Fault
-
Fast_IO_OUT - Wrong Axis connected
Fault
-
Fast_IO_OUT - Wrong Axis parameter
Fault
-
Fast_IO_OUT - Mapping error
Fault
-
Fast_IO_OUT - Internal overflow
Fault
-
Touch probe - Invalid channel selection
Fault
-
Touch probe - Invalid mode selection
Fault
-
Touch probe - Only positive edge is supported
Fault
-
Touch probe - Invalid edge selection
Fault
-
Touch probe - Channel in use
Fault
-
Touch probe - PDO mapping fault
Fault
-
Touch probe - Internal channel in use
Fault
-
Touch probe - Time-out
Fault
-
Touch probe - Communication error
Fault
-
Touch probe - Invalid signal selection
Fault
-
Touch probe - Wrong axis type
Fault
-
Touch probe - Rising edge blocked
Fault
-
Touch probe - Falling edge blocked
Fault
-
Touch probe - Internal error
Fault
-
Set values greater than the parameterized maximum values
Fault
-
Set values inconsistent
Fault
-
Position difference per task cycle greater than half the cycle length
Fault
-
Invalid task cycle time
Fault
-
Initialization - SDO write access failed
Fault
-
Initialization - SDO read access failed
Fault
-
Initialization - Cycle time of the fastest task too high
Fault
-
Initialization - Motor rated torque = 0
Fault
-
Initialization - Motor rated speed = 0
Fault
-
Initialization - Reading of firmware version failed
Fault
-
Initialization - Invalid Encoder resolution
Fault
-
Initialization - Reading of encoder revolutions failed
Fault
-
Initialization - Reading of encoder CRC failed
Fault
-
Initialization - Absolute encoder position not available
Fault
-
Controller firmware incompatible
Fault
-
Invalid mode
Fault
-
Initialization error at the encoder backplane bus
Fault
-
Function 'Optical device identification' not supported
Fault
-
Invalid gear factor
Fault
-
Position outside cycle length
Fault
-
Invalid cycle length (AddOffsetCyclic)
Fault
-
Invalid input position (AddOffsetCyclic)
Fault
-
Invalid cycle length (ZeroDetect)
Fault
-
Invalid input position (ZeroDetect)
Fault
-
Invalid start position (IntegrateAxis)
Fault
-
Simultaneous direction setting for 'JogPos' and 'JogNeg'
Fault
-
Value outside value range
Fault
-
State not 'Disabled'
Fault
-
Brake test - Invalid input value
Fault
-
Brake test - Already active
Fault
-
Brake grind in - Invalid input value
Fault
-
Brake grind in - Already active
Fault
-
Selected control mode not allowed
Fault
-
Virtual axes not supported
Fault
-
Axis not disabled
Fault
-
Invalid feed constant
Fault
-
Invalid traversing range
Fault
-
Invalid cycle length
Fault
-
Invalid position resolution
Fault
-
Torque limit too large
Fault
-
Torque limit < 0
Fault
-
Invalid encoder signal
Fault
-
Encoder signal greater than parameterized measuring range
Fault
-
Invalid parameterized measuring range
Fault
-
STO active in drive
Fault
-
Inverter disable active
Fault
-
Invalid SW limits
Fault
-
Invalid jerk
Fault
-
Parameter 'vl Target Velocity' not included in mapping
Fault
-
Parameter 'vl Actual Velocity' not included in mapping
Fault
-
Axis not homed
Fault
-
Axis not in SimpleMode
Fault
-
Axis in SimpleMode
Fault
-
Function not supported by axis
Fault
-
Execution index already in use
Fault
-
SS1 active
Fault
-
SS2 active
Fault
-
Velocity limited by SLS1
Fault
-
Velocity limited by SLS2
Fault
-
Velocity limited by SLS3
Fault
-
Velocity limited by SLS4
Fault
-
Invalid execution index
Fault
-
The total number of manageable axes in the project has been reached
Fault
-
Actual position of the load encoder not included in the mapping
Fault
-
Function not supported by drive
Fault
-
Autotuning with variable switching frequency
Fault
-
A test mode is already active in the drive
Fault
-
Function "Set position" is not allowed because home position is set permanently
Fault
-
Blending of cartesian motion with MoveDirect is not supported
Fault
-
Blending of L_MC4P_GroupWaitTime is not supported
Fault
-
Auxilliary axes with mode DiscreteAbs/DiscreteRel cannot be blended
Fault
-
Blending not possible without predecessor motion
Fault
-
Blending not possible due to delayed request
Fault
-
LookAhead = 0, blending not possible
Fault
-
Abort of 'PathRefFromFile' during the execution of 'MovePath'
Fault
-
Phasing not allowed
Fault
-
Invalid CamRef
Fault
-
Invalid cam type
Fault
-
Invalid cam data
Fault
-
Invalid number of memory segments
Fault
-
Insufficient memory segments defined for cam
Fault
-
Invalid law of motion
Fault
-
Invalid input data
Fault
-
Master out of cam
Fault
-
OffsetScaling - Invalid velocity/acceleration
Fault
-
Invalid cam table
Fault
-
Invalid start or end position of cam
Fault
-
Invalid scaling factor
Fault
-
Clutch in error
Fault
-
Not allowed movement by master
Fault
-
Clutch needs reversing
Fault
-
Invalid default jerk
Fault
-
Invalid open instant deceleration
Fault
-
Invalid reversing
Fault
-
File not found
Fault
-
Invalid file
Fault
-
Invalid checksum
Fault
-
Invalid data size
Fault
-
Invalid TappetRef
Fault
-
Invalid tappet data
Fault
-
Invalid tappet type
Fault
-
Invalid tappet switching time
Fault
-
Invalid tappet position
Fault
-
Dynamic tappet sampling error
Fault
-
LinearCoupling - Invalid X cycle length
Fault
-
LinearCoupling - Invalid Y cycle length
Fault
-
LinearCoupling - Invalid input position
Fault
-
Invalid number of tappets
Fault
-
Internal error
Warning
-
Internal error
Warning
-
Internal error
Warning
-
Internal error
Warning
-
Internal error
Warning
-
Internal error
Warning
-
Internal error
Warning
-
CTRL - Feature not supported
Warning
-
CTRL - Invalid index
Warning
-
ISW - Invalid offset
Warning
-
CTRL - Invalid size
Warning
-
ISW - Invalid data
Warning
-
ISW - Not ready
Warning
-
CTRL - Busy
Warning
-
ISW - Cannot queue acyclic EtherCAT command
Warning
-
CFG - No memory left
Warning
-
CTRL - Invalid parameter
Warning
-
CTRL - Not found
Warning
-
ISW - Invalid state
Warning
-
ISW - Cannot add slave to timer list
Warning
-
SLV - Time-out
Warning
-
ISW - Open failed
Warning
-
LLA - Send failed
Warning
-
CFG - Error when queuing a mailbox command
Warning
-
ISW - Invalid mailbox command
Warning
-
ISW - Unknown mailbox protocol command
Warning
-
ISW - Access denied
Warning
-
CFG - Invalid product key
Warning
-
PRJ - Wrong format of master XML file
Warning
-
CTRL - Function disabled
Warning
-
PRJ - Mismatch of bus configuration and number of connected slaves
Warning
-
PRJ - Error reading master XML file
Warning
-
PRJ - Configurator error - cyclic commands are missing in master XML file
Warning
-
PRJ - AL_STATUS register read command is missing in master XML file
Warning
-
ISW - Fatal internal McSm error
Warning
-
SLV - Slave error
Warning
-
SLV - Frame lost, IDX mismatch
Warning
-
SLV - At least one EtherCAT command is missing in the received frame
Warning
-
CTRL - IOCTL EC_IOCTL_DC_LATCH_REQ_LTIMVALS not possible in DC Latching auto read mode
Warning
-
SLV - Auto increment address - increment mismatch (slave missing)
Warning
-
CTRL - Slave in invalid state, e.g. not in OP (API not callable in this state)
Warning
-
SLV - Fixed station address lost or slave missing - FPRD to AL_STATUS failed
Warning
-
PRJ - Too many cyclic commands in XML configuration file
Warning
-
RAP - Master core not accessible
Warning
-
SLV - COE mailbox send - WKC error
Warning
-
SLV - COE mailbox receive - WKC error
Warning
-
CTRL - No mailbox support
Warning
-
CoE - Protocol not supported
Warning
-
PRJ - EoE protocol not supported
Warning
-
FoE . Protocol not supported
Warning
-
PRJ - SoE protocol not supported
Warning
-
PRJ - VoE protocol not supported
Warning
-
PRJ - Configuration violates evaluation limits
Warning
-
CFG - Evaluation time expired
Warning
-
COE - invalid slave state
Warning
-
CoE - SDO Abort 'Toggle bit not alternated (0x05030000)'
Warning
-
CoE - SDO Abort 'SDO protocol time-out (0x05040000)'
Warning
-
CoE - SDO Abort 'Client/server command specifier not valid or unknown (0x05040001)'
Warning
-
CoE - SDO Abort 'Invalid block size (block mode only) (0x05040002)'
Warning
-
CoE - SDO Abort 'Invalid sequence number (block mode only) (0x05040003)'
Warning
-
CoE - SDO Abort 'CRC error (block mode only) (0x05040004)'
Warning
-
CoE - SDO Abort 'Out of memory (0x05040005)'
Warning
-
CoE - SDO Abort 'Unsupported access to an object (0x06010000)'
Warning
-
CoE - SDO Abort 'Attempt to read a write only object (0x06010001)'
Warning
-
CoE - SDO Abort 'Attempt to write a read only object (0x06010002)'
Warning
-
CoE - SDO-Abort 'Object does not exist in the object dictionary (0x06020000)'
Warning
-
CoE - SDO Abort 'Object cannot be mapped to the PDO (0x06040041)'
Warning
-
CoE - SDO Abort 'Number and length of objects to be mapped exceed PDO length (0x06040042)'
Warning
-
CoE - SDO Abort 'General parameter incompatibility (0x06040043)'
Warning
-
CoE - SDO Abort 'General internal incompatibility in the device (0x06040047)'
Warning
-
CoE - SDO Abort 'Access failed due to an hardware error (0x06060000)'
Warning
-
CoE - SDO Abort 'Data type or length of service parameters do not match (0x06070010)'
Warning
-
CoE - SDO Abort 'Data type does not match, service parameter too high (0x06070012)'
Warning
-
CoE - SDO Abort 'Data type does not match, service parameter too low (0x06070013)'
Warning
-
CoE - SDO Abort 'Subindex does not exist (0x06090011)'
Warning
-
CoE - SDO Abort 'Write access - Parameter value exceeds limits (0x06090030)'
Warning
-
CoE - SDO Abort 'Write access - Parameter value too high (0x06090031)'
Warning
-
CoE - SDO Abort 'Write access - Parameter value too low (0x06090032)'
Warning
-
CoE - SDO Abort 'Maximum value less than minimum value (0x06090036)'
Warning
-
CoE - SDO Abort 'General error (0x08000000)'
Warning
-
CoE - SDO Abort 'Data cannot be transferred/stored in application (0x08000020)'
Warning
-
CoE - SDO Abort 'Local control - Data cannot be transferred/stored in application (0x08000021)'
Warning
-
CoE- SDO Abort 'Actual device state - Data cannot be transferred/stored in application (0x08000022)'
Warning
-
CoE - SDO Abort 'Object dictionary - Dynamic generation fails or object dictionary is missing (0x08000023)'
Warning
-
CoE - SDO Abort 'Unknown abort code'
Warning
-
CoE - Invalid parameter
Warning
-
CoE - CoE protocol not supported
Warning
-
CoE - Unknown FoE error
Warning
-
CoE - FoE error 'Not found'
Warning
-
CoE - FoE error 'Access denied'
Warning
-
CoE - FoE error 'Disk full'
Warning
-
CoE - FoE error 'Illegal'
Warning
-
CoE - FoE error 'Wrong packet number'
Warning
-
CoE - FoE error 'Already existing'
Warning
-
CoE - FoE error 'User missing'
Warning
-
CoE - FoE error 'Only possible in bootstrap'
Warning
-
CoE - FoE error 'No bootstrap'
Warning
-
CoE - FoE error 'No access rights'
Warning
-
CoE - FoE error 'Program error'
Warning
-
CoE - FoE error 'Invalid parameter'
Warning
-
CTRL - Master configuration not found
Warning
-
SLV - Command error while EEPROM upload
Warning
-
SLV - Command error while EEPROM download
Warning
-
PRJ - Cyclic command too long
Warning
-
PRJ - Invalid input offset in cyc cmd, please check InputOffs
Warning
-
PRJ - Invalid output offset in cyc cmd, please check OutputOffs
Warning
-
RAP - Invalid cookie
Warning
-
RAP - Watchdog expired
Warning
-
RAP - Connecting 2nd server denied, multi server support is disabled
Warning
-
RAP - Logon aborted
Warning
-
RAP - Invalid version
Warning
-
RAP - Server stopped
Warning
-
RAP - Watchdog expired
Warning
-
RAP - Reconnect time expired
Warning
-
RAP - Client logged on
Warning
-
RAP - Client reconnected
Warning
-
RAP - Socket changed after reconnect
Warning
-
DCM - Init function not called or call not successful
Warning
-
DCM - Controller error - synchronization out of limit
Warning
-
DCM - Not enough memory
Warning
-
DCM - Hardware layer - (BSP) invalid
Warning
-
DCM - Hardware layer - Error while modifying the timer
Warning
-
DCM - Hardware layer - Timer is not running
Warning
-
DCM - Hardware layer - Function is called on wrong CPU
Warning
-
EtherCAT - State change of master successful
Warning
-
EtherCAT - Bus scan successful
Warning
-
EtherCAT - Bus scan error
Warning
-
EtherCAT - Distributed clocks state
Warning
-
EtherCAT - Distributed clocks - Latching state
Warning
-
CoE - SDO download failure
Warning
-
CoE - SDO upload failure
Warning
-
CoE - OD-list upload failure
Warning
-
CoE - Object description upload failure
Warning
-
CoE - Object entry description upload failure
Warning
-
CoE - Emergency transfer failure
Warning
-
CoE - Emergency request
Warning
-
Cyclic command WKC error
Warning
-
Master init command WKC error
Warning
-
Slave init command WKC error
Warning
-
EoE receive WKC error
Warning
-
CoE receive WKC error
Warning
-
FoE receive WKC error
Warning
-
SoE receive - WKC error
Warning
-
EoE send WKC error
Warning
-
CoE send WKC error
Warning
-
FoE send WKC error
Warning
-
SoE send - WKC error
Warning
-
Retry sending a frame
Warning
-
Response on Ethernet frame
Warning
-
Additional error information
Warning
-
EtherCAT command - IDX actual value
Warning
-
EtherCAT command - IDX set value
Warning
-
Init command response error - No response
Warning
-
Init command response error - Validation error
Warning
-
Init command response error - Failed
Warning
-
Master init command response error - No response
Warning
-
Master init command response error - Validation error
Warning
-
Missing EtherCAT command in Ethernet frame
Warning
-
Mailbox init command timeout
Warning
-
At least one EtherCAT slave not in 'Operational'
Warning
-
EtherCAT cable connected
Warning
-
EtherCAT cable not connected
Warning
-
Cyclic commands - Time-out
Warning
-
Redundant operation - Ethernet cable is missing at 2nd EtherCAT interface
Warning
-
At least one slave is in state 'Error'
Warning
-
Slave error
Warning
-
Communication to device interrupted
Warning
-
SDO abort
Warning
-
DC slaves are 'in-sync'
Warning
-
DC slaves are 'out-of-sync'
Warning
-
DC single latch on slave
Warning
-
MbxTferRcv - file upload failure
Warning
-
MbxTferRcv - file download failure
Warning
-
Client registration lost
Warning
-
Redundant operation - Ethernet cable connected
Warning
-
SoE write error init command mbox
Warning
-
Hot Connect - all groups detected
Warning
-
Hot Connect - all group errors detected
Warning
-
Slave removed from bus
Warning
-
Slave added to bus
Warning
-
Topology was changed
Warning
-
Port closed
Warning
-
MbxTferRcv - Write IDN failure
Warning
-
MbxTferRcv - Read IDN failure
Warning
-
SoE - Emergency transfer failure
Warning
-
SoE - Emergency request
Warning
-
SoE - Notification transfer failure
Warning
-
SoE - Notification request
Warning
-
FoE abort
Warning
-
Bus scan state
Warning
-
Latch/Edge - No edge
Warning
-
Remote API diagnosis port - Connection established
Warning
-
Remote API diagnosis port - Connection disconnected
Warning
-
Client registered from cookie
Warning
-
Client unregistered from cookie
Warning
-
Unknown notification
Warning
-
Slave latched
Warning
-
Bus scan - Error
Warning
-
Invalid number of slaves
Warning
-
Cannot get SlaveInfo
Warning
-
Deviation of slave
Warning
-
Slave is not configured
Warning
-
SlaveInfo
Warning
-
SLV - Error retrieving configuration data
Warning
-
Bus scan - Deviation
Warning
-
Communication to device interrupted
Warning
-
Slave is not in expected status
Warning
-
Wrong response on 'configured fix address request' for slave
Warning
-
Wrong response on 'alias address' request for slave
Warning
-
Cannot execute EC_IOCTL_DC_SLV_SYNC_DEVLIMIT_GET
Warning
-
Cannot read latch timer
Warning
-
Cannot execute EC_IOCTL_DC_SLV_SYNC_RESTART
Warning
-
RAP - Invalid parameter size
Warning
-
RAP - Marshaling error
Warning
-
Unable to enqueue (missing calls to ProcessNotificationJobs)
Warning
-
No connection to slaves
Warning
-
ecatSetTargetState cannot set EtherCAT master into target state, master is busy (time-out)
Warning
-
ecatStop() returns 'Busy', retry...
Warning
-
Mailbox transfer request - Error
Warning
-
Mailbox transfer
Warning
-
Waiting for mailbox transfer from master...
Warning
-
Mailbox transfer - Fatal time-out error
Warning
-
Bus cycle and Sync period are different
Warning
-
Error getting the bus scan state
Warning
-
Wrong response on DC supported request or slave
Warning
-
Unable to set 'DC slave sync disable'
Warning
-
Error when restarting bus scan
Warning
-
Bus scan timeout
Warning
-
Configuration error - Check of VendorID failed
Warning
-
Configuration error - Check of ProductCode failed
Warning
-
Configuration error - Check of Revision failed
Warning
-
Configuration error - Check of VendorID failed
Warning
-
Configuration error - Odd device at bus end
Warning
-
Internal error counter resetted
Warning
-
All slaves 'Operational' again
Warning
-
Cyclic command WKC error
Warning
-
Frame response error
Warning
-
Not all slaves are 'Operational'
Warning
-
Emergency message - Overflow, further messages blocked
Warning
-
New configuration loaded
Warning
-
New configuration loaded, no slaves defined
Warning
-
Master - Start failed, configuration error
Warning
-
New configuration loaded from slaves EEPROM
Warning
-
Master - Start failed
Warning
-
Master - Start failed, bus configuration error
Warning
-
Master - Start failed, EtherCAT cable disconnected
Warning
-
Master - Start failed, DC/DCM configuration
Warning
-
Master - Start failed, cannot set slaves to 'Pre-Operational'
Warning
-
Master - Set 'Operational' failed
Warning
-
Master - Set 'Operational' failed, Master not initialized
Warning
-
Master - Set 'Operational' failed, EtherCAT cable disconnected
Warning
-
Master - Set 'Operational' failed, DCM not in-sync
Warning
-
Master - Set 'Operational' failed, bus cycle and DC different
Warning
-
Master - Set 'Operational' takes some time...
Warning
-
Master - Set 'Operational' failed, time-out
Warning
-
Master - Set 'Operational' failed, slave error
Warning
-
Master - Set 'Operational' aborted by reset command
Warning
-
Master - Stopping failed
Warning
-
Master - Stopping failed, cannot set Slaves 'Pre-Operational'
Warning
-
Master - Shutdown failed
Warning
-
Remote API Server - Start failed
Warning
-
Start Download Service
Warning
-
Download Service done
Warning
-
MMC - Internal error
Warning
-
MMC - 'Modular Machine Configuration' is active
Warning
-
MMC - Service started
Warning
-
MMC - Service stopped
Warning
-
MMC - Error in configuration files
Warning
-
MMC - File does not exist
Warning
-
MMC - Parsing error
Warning
-
MMC - parsing of file successful
Warning
-
MMC - Devices not sorted in ascending order or devices missing
Warning
-
MMC - Number of devices in device tree differs
Warning
-
MMC - Device type mismatch for Alias Address
Warning
-
MMC - Invalid Alias Address
Warning
-
MMC - Duplicated Alias Address
Warning
-
MMC - No configuration checks
Warning
-
MMC - Invalid configuration
Warning
-
MMC - Mandatory slave missing
Warning
-
MMC - Optional slave is present, but not allowed
Warning
-
MMC - No valid service active
Warning
-
MMC - Address assignment error, less slaves connected than configured
Warning
-
MMC - Address assignment error, more slaves connected than configured
Warning
-
MMC - Address assignment error, invalid device
Warning
-
MMC - Address assignment successful
Warning
-
MMC - Address assignment failed
Warning
-
MMC - Address assignment done
Warning
-
MMC - Address assignment error, writing address by CoE
Warning
-
MMC - Slave identification error
Warning
-
MMC - Slave identification error, slave ident data failed
Warning
-
MMC - Service state cannot be changed, set bus to 'INIT' first
Warning
-
Last ETC message
Warning
-
EtherCAT - DC synchronization required
Warning
-
EtherCAT - Communication error
Fault > CiA402
0x285B:001
EtherCAT - Wrong sync manager address
Fault
-
EtherCAT - Wrong sync manager size
Fault
-
EtherCAT - Wrong sync manager settings
Fault
-
PDO mapping: Unknown object
Fault
-
No PDO mapping object
Fault
-
Too many objects mapped
Fault
-
PDO mapping error
Fault
-
PDO mapping object is already used by PLC.
Fault
-
EtherCAT - Sync error
Fault
-
Sync PLL - Time-out
Fault
-
Invalid Sync0 cycle time
Fault
-
Check OUT-port of EtherCAT master
-
Check IN-port of EtherCAT slave
-
Network - Time-out explicit message
-
Network - Overall communication time-out
Warning
0x2859:007
CAN: bus off
Warning
0x2857:010
CAN: warning
Warning
0x2857:011
CAN: heartbeat time-out consumer 1
Warning
0x2857:005
CAN: heartbeat time-out consumer 2
Warning
0x2857:006
CAN: heartbeat time-out consumer 3
Warning
0x2857:007
CAN: heartbeat time-out consumer 4
Warning
0x2857:008
Network - Watchdog time-out
Warning
0x2859:001
Network - Disruption of cyclic data exchange
No response
0x2859:002
Network - Initialization error
Warning
0x2859:004
Network - Invalid cyclic process data
Warning
0x2859:005
Network - Initialization with safety option failed
Information
-
Network - Communication time-out with safety option
Information
-
Network - Invalid configuration
Warning
0x2859:003
CAN: RPDO1 time-out
Warning
0x2857:001
CAN: RPDO2 time-out
Warning
0x2857:002
CAN: RPDO4 time-out
Warning
0x2857:004