Feedback system for the technology application
If the Actual velocity parameter is selected as the master value source, the master value will be provided by the optional slot (B) of the device.
0x500B:011
0x500B:011Fig. 1: Slot (B)
Fig. 2: Application feedback (B) as master value source
The technology application responds to encoder errors on slot B (application feedback). The error response is configured in the Load encoder/master encoder error response parameter.
0x2C55
0x2C55Fig. 3: Principle signal flow in case of error response to the virtual master
The Load encoder/master encoder error response parameter displays the following errors.
0x2C55
0x2C55|
Setting
|
Response
|
Parameter index
|
|
Load encoder/master encoder error response = [0] no response
|
No response
|
-
|
|
Load encoder/master encoder error response = [1] fault
|
The drive changes to the error status ErrorStop.
Note:
If the technology application serves as the master value for an integrated network, SetValue = [1] must be configured in the Master values output systembus parameter.
|
0x5020:001
|
|
If Application feedback (B) = [3] is configured in the Master values output systembus parameter, a setpoint step-change will occur in the event of an encoder error.
|
0x5020:001
|
|
|
Load encoder/master encoder error response = [2] warning
|
Clutch is switched to the virtual master.
|
-
|
Parameter
Severity