Virtual master

The technology application allows operation with a virtual master. In this case, a drive in the network takes on the role of the virtual master while at the same time serving as the first slave drive. The generated master value is transmitted to the slave drives via the system bus.
 
Operating modes
The virtual master provides the following operating modes:
Operating mode/function
Bit names of the "Simulation of control signals for virtual master" parameter
Parameter index
Bit
Continuous operation
VM Continuous
Bit 25
Clocked operation
VM cycle
Bit 26
Loading of the starting position
Load VM position
Bit 27
Manual operation - positive direction of rotation
Positive manual operation VM
Bit 28
Manual operation - negative direction of rotation
Negative manual operation VM
Bit 29
Additional functions for all operating modes
Function
Parameter name
Parameter index
Setting of the setpoint velocity
Setpoint speed
Guide to standstill position
Setpoint position of virtual master
Acceleration to setpoint velocity
Acceleration of virtual master
Decelerate master value
Deceleration of virtual master
Additional functions for the manual operating mode
Function
Parameter name
Parameter index
Accelerate
Acceleration of manual operation
Manual speed
Speed of manual operation
Decelerate
Deceleration of manual operation
Parameterize jerk
Jerk of manual operation
Fig. 1: Virtual master as setpoint source
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2DA4:005
Diagnostics of analog input 1: Scaled percent value
–
Read only: x.xx %
 
Display of the actual value at the analog input, scaled with the following parameters:
–
Minimum value for scaling. 0x2636:013
 
–
Maximum value for scaling. 0x2636:014
 
0x4001
Interface selection
Selecting the interface determines the interface that receives the signals.
0
Fieldbus network
Control of the application via the fieldbus.
1
Onboard EtherCAT
Activation of the application via the system bus.
0x500B:011
Actual velocity
–
Read only
 
The current speed value is resolved with 4 decimal positions.
0x5020:009
Reference velocity for analog input 1
0.0000 ... [500.0000] ... 214748.3647
The reference speed for the percentage value of the analog input.
0x5020:014
Master value source
–
Setting can only be changed if the inverter is disabled.
 
0
System bus
The system bus provides the external master velocity value.
1
Load encoder
The signal from the load encoder interface is taken as the master velocity value.
2
Virtual master
The virtual master, whose setpoint velocity comes from the Set virtual master velocity PDO, serves as master value master. 0x5045:011
3
Analog input 1
0x5021:152
System bus diagnostics: Velocity (input value)
–
Read only
 
Speed conductivity
0x5042:017
Set velocity of selected master value
–
Read only
 
0x5045:010
Virtual master control signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
Control bit 00 (reserved)
This bit can be assigned to an optinal function.
Bit  1
Control bit 01 (reserved)
This bit can be assigned to an optinal function.
Bit  2
Control bit 02 (reserved)
Bit  3
Control bit 03 (reserved)
Bit  4
Control bit 04 (reserved)
Bit  5
Control bit 05 (reserved)
Bit  6
Control bit 06 (reserved)
Bit  7
Fault reset
Only after the cause has been eliminated are the errors reset.
Bit  8
Control bit 08 (reserved)
This bit can be assigned to an optinal function.
Bit  9
Control bit 09 (reserved)
This bit can be assigned to an optinal function.
Bit  10
Control bit 10 (reserved)
Bit  11
Control bit 11 (reserved)
This bit can be assigned to an optinal function.
Bit  12
Control bit 12 (reserved)
Bit  13
Control bit 13 (reserved)
Bit  14
Control bit 14 (reserved)
Bit  15
Control bit 15 (reserved)
Bit  16
Control bit 16 (reserved)
Bit  17
Control bit 17 (reserved)
This bits is not used in the TA.
Bit  18
Control bit 18 (reserved)
Bit  19
Control bit 19 (reserved)
Bit  20
Control bit 20 (reserved)
This bit can be assigned to an optinal function.
Bit  21
Control bit 21 (reserved)
Bit  22
Control bit 22 (reserved)
Bit  23
Control bit 23 (reserved)
Bit  24
Control bit 24 (reserved)
Bit  25
Continuous operation
Triggers the continuous driving operation of the virtual master.
Bit  26
Cyclic operation
Bit  27
Load position
Starting position of the virtual master axis loaded.
–
This function can also be executed when the axis is disabled or the virtual master, stop = TRUE.
 
–
This function cannot be executed during the position synchronisation.
 
Bit  28
Manual jog positive
Virtual master moves in the positive direction (manual jog).
Bit  29
Manual jog negative
Virtual master moves in the negative direction (manual jog).
Bit  30
Halt
The active movement of the virtual master is aborted and the axis is brought to a standstill with the deceleration defined via the Stop parameter.
Bit  31
Deactivate external master values
–
The external master values are deactivated.
 
–
The virtual master is used as the actual value source.
 
–
The clutch is switched without a jump.
 
0x5045:011
Set velocity
-214748.3648 ... [0.0000] ... 214748.3647
The value of the setpoint velocity of the virtual master is given in [units/s]. The value of the setpoint velocity is resolved with 4 decimal places.
0x5045:110
Virtual master status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
Status bit 00 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  1
Status bit 01 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  2
Status bit 02 (reserved)
Bit  3
Fault
Bit  4
Status bit 04 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  5
Status bit 05 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  6
Manual jog active
Manual operation is activated.
Bit  7
Warning
The warning is activated.
Bit  8
Halt active
Bit  9
Status bit 09 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  10
Status bit 10 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  11
Status bit 11 (reserved)
Bit  12
Status bit 12 (reserved)
Bit  13
Status bit 13 (reserved)
Bit  14
Status bit 14 (reserved)
Bit  15
Status bit 15 (reserved)
Bit  16
Status bit 16 (reserved)
Bit  17
Status bit 17 (reserved)
Bit  18
Status bit 18 (reserved)
Bit  19
Status bit 19 (reserved)
Bit  20
Status bit 20 (reserved)
Bit  21
Status bit 21 (reserved)
Bit  22
Status bit 22 (reserved)
Bit  23
Status bit 23 (reserved)
Bit  24
Status bit 24 (reserved)
Bit  25
Busy
The virtual master is activated.
Bit  26
Taget reached
The axis has reached the target position and is at standstill. 0x5046:002
Bit  27
Synchronized
Bit  28
Synchronization active
Bit  29
Status bit 29 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  30
Status bit 30 (reserved)
This bit of the status signal can be assigned to a function status.
Bit  31
External master values deactivated
The external master value is deactivated in the system bus in the application feedback (B).
0x5045:111
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
The setpoint position is specified in [unit]. The setpoint position is resolved with 4 decimal places.
0x5045:112
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
The setpoint velocity is specified in [units/s]. The setpoint velocity is resolved with 4 decimal places.
0x5045:113
Actual acceleration
-21474836.48 ... [0.00] ... 21474836.47
The current position is specified in [unit]. The current position is resolved with 4 decimal places.
0x5045:114
Error code
0 ... [0] ... 4294967295
The current error number is displayed in the word.
0x5045:115
Cycle length
-214748.3648 ... [0.0000] ... 214748.3647
The current position is specified in [unit]. The current position is resolved with 4 decimal places.
0x5046:001
Virtual master start position
0.0000 ... [0.0000] ... 214748.3647
0x5046:002
Virtual master set position
0.0000 ... [0.0000] ... 214748.3647
0x5046:003
Virtual master acceleration
0.00 ... [100000.00] ... 21474836.47
0x5046:004
Virtual master deceleration
0.00 ... [100000.00] ... 21474836.47
0x5046:005
Virtual master jerk
0.00 ... [1000000.00] ... 21474836.47
0x5046:020
Virtual master clutch velocity
0.0000 ... [100.0000] ... 214748.3647
0x5047:001
Virtual Master: Set velocity
–
Read only
 
0x500C:010
Actual position
–
Read only
 
0x500C:011
Actual velocity
–
Read only
 
0x500C:012
Actual acceleration
–
Read only
 
0x500C:014
Set position
–
Read only
 
0x500C:015
Velocity setpoint
–
Read only
 
0x500C:016
Set acceleration
–
Read only
 
0x500C:030
Traversing range
–
Setting can only be changed if the inverter is disabled.
 
Specification of the traversing range for the virtual master axis.
–
0: Linearly limited traversing range (spindle drive).
 
–
1: Unlimited traversing range (turntable). The cycle length must also be specified here.
 
0
Modulo
1
Limited
0x500C:031
Cycle length
0.0001 ... [360.0000] ... 214748.3647
–
Setting can only be changed if the inverter is disabled.
 
The cycle length for an unlimited traversing range defines at which position the measuring system is repeated (position return to 0).
0x500C:045
Max. velocity
0.0000 ... [0.0000] ... 214748.3647
0x500C:046
Max. acceleration
0.00 ... [0.00] ... 21474836.47
0x500C:047
Max. jerk
0.00 ... [0.00] ... 21474836.47
0x500C:048
Application quick stop - deceleration
0.01 ... [3600.00] ... 21474836.47
0x500C:049
Application quick stop - jerk
0.00 ... [0.00] ... 21474836.47
0x500C:050
Enable software limit switches
false
Inactive
true
Active
0x500C:051
Software limit switch positive
-214748.3648 ... [0.0000] ... 214748.3647
0x500C:052
Software limit switch negative
-214748.3648 ... [0.0000] ... 214748.3647
0x500C:053
Action after "software limit switch reached"
0
Stop after software limit switch
1
Stop at software limit switch
0x500C:105
Response to "software limit switch reached"
19
Fault > Application quick stop > Quick stop
21
Fault> Application quick stop > Inverter disabled
0x500C:106
Response to "profile limit reached"
0
No Response
2
Warning
19
Fault > Application quick stop > Quick stop
21
Fault> Application quick stop > Inverter disabled
0x500C:150
SLS1
0.0000 ... [0.0000] ... 214748.3647
0x500C:151
SLS1 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:152
SLS2
0.0000 ... [0.0000] ... 214748.3647
0x500C:153
SLS2 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:154
SLS3
0.0000 ... [0.0000] ... 214748.3647
0x500C:155
SLS3 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:156
SLS4
0.0000 ... [0.0000] ... 214748.3647
0x500C:157
SLS4 - deceleration time
0.000 ... [0.000] ... 2147483.647 s
0x500C:162
Deactivate safety interface
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  1
Ignore SS1 request
Bit  2
Ignore SS2 request
Bit  3
Ignore SLS1 - SLS4 request
Bit  4
Ignore SDI request
Bit  5
0x500C:181
Manual jog velocity
0.0000 ... [360.0000] ... 214748.3647
0x500C:182
Manual jog acceleration
0.00 ... [720.00] ... 21474836.47
0x500C:183
Manual jog deceleration
0.00 ... [1440.00] ... 21474836.47
0x500C:184
Manual jog jerk
0.00 ... [0.00] ... 21474836.47
0x500C:186
Deceleration of Halt
0.00 ... [1800.00] ... 21474836.47
0x500C:187
Jerk of Halt
0.00 ... [0.00] ... 21474836.47