Speed via analog input 1

The speed source takes the form of a percentage value from analog input 1. The Diagnostics of analog input 1: Scaled percent value parameter refers to the Reference velocity for analog input 1 parameter.
–
Diagnostics of analog input 1: Scaled percent value 0x2DA4:005
 
–
Reference velocity for analog input 1 0x5020:009
 
The Reference velocity for analog input 1 parameter is configured and scaled in the basic settings.
 
The resulting setpoint velocity Virtual Master: Set velocity is used for the continuous operation or cyclic operation of the virtual master. 0x5047:001
Fig. 1: Front view of the plug connector X3 with analog input 1
Fig. 2: Analog input 1 as speed source
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Diagnostics of analog input 1: Scaled percent value
x.xx % (Read only)
Reference velocity for analog input 1
500.0000
0.0000 ... 214748.3647
Virtual Master: Set velocity
- (Read only)