External master values

The Virtual master control signals parameter can be used to switch over the master value source when the controller is enabled. 0x5045:010 Bit 31
If bit 31 of the Virtual master control signals parameter is set to TRUE, the external master value sources are deselected. The virtual master takes over the motion control and synchronises itself via the selected master value source.
Profile calculation parameters:
–
Virtual master acceleration 0x5046:003
 
–
Virtual master deceleration 0x5046:004
 
–
Virtual master jerk 0x5046:005
 
–
Clutch-in direction virtual master 0x5046:030
 
 
If bit 31 of the Virtual master control signals parameter is set to FALSE, the master value synchronises itself with the master value source selected in the Master value source parameter.
–
Virtual master control signals 0x5045:010
 
–
Master value source 0x5020:014
 
The compensation velocity is specified via the Virtual master clutch velocity parameter. 0x5046:020
The synchronisation processes can be executed for the following starting conditions and target conditions:
–
From standstill to motion
 
–
From motion to standstill
 
–
From motion to motion
 
–
From standstill to standstill
 
The synchronisation processes are independent of the motion of the external master value source. Synchronisation also occurs when the real master is at a standstill.
 
Fig. 1: Clutch is switched from master value source to the virtual master
Fig. 2: Control bits and status bits
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Virtual master acceleration
100000.00
0.00 ... 21474836.47
Virtual master deceleration
100000.00
0.00 ... 21474836.47
Virtual master jerk
1000000.00
0.00 ... 21474836.47
Virtual master clutch velocity
100.0000
0.0000 ... 214748.3647
Virtual Master: Set velocity
- (Read only)