Velocity synchronization

The synchronism of master value and drive axis is established via a coupling mode.
 
The settings of the parameters Stretch factor numerator and Stretch factor denominator are only effective in Coupling mode = 0 effective.
 
Coupling via units or cycle lengths can be selected as the coupling mode. The coupling mode is configured via the Coupling mode parameter. 0x5041:030
Coupling mode 0x5041:030
Response/clutch factor
[0] unit clutching
Stretch factor numerator 0x5041:020
Stretch factor denominator 0x5041:021
[1] Coupling via cycle length
Cycle length of the slave axis 0x500A:031
Cycle length of the master axis 0x500C:031
 
Example
Synchronism with equal cycle lengths 360/360
Synchronism with unequal cycle lengths 360/450
 
The coupling function synchronises the velocity of the drive to the Setpoint velocity with offset velocity value. 0x5042:019
 
The velocity value Setpoint velocity with offset contains the values:
–
Setpoint velocity after dimensional system adjustment 0x5042:021
 
–
Total velocity offset0x5042:030
 
Values to be specified
Parameter name
Parameter index
Bit
Acceleration
Acceleration of coupling
-
Coupling pressure
Jerk of coupling
-
Coupling
Control signals
Bit 16 = TRUE
Decoupling
Control signals
Bit 16 = FALSE
Deceleration
Deceleration of coupling
-
Fig. 1: Synchronism of signal flow
Fig. 2: Control bits and status bits
 
Fig. 3: Coupling process and decoupling process
The graphic shows the coupling process and the decoupling process from standstill to velocity 100 [units/s] and back to standstill.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5040:016
External base velocity
-214748.3648 ... [0.0000] ... 214748.3647
Value of the external basic velocity.
0x5041:020
Stretch factor - numerator
0 ... [1] ... 4294967295
0x5041:021
Stretch factor - denominator
0 ... [1] ... 4294967295
0x5041:030
Coupling mode
0
Coupling factor
1
Cycle lengths
0x5041:040
Clutch acceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:041
Clutch deceleration
-21474836.48 ... [100.00] ... 21474836.47
0x5041:042
Clutch jerk
-21474836.48 ... [10000.00] ... 21474836.47
0x5041:043
Clutch base velocity
-214748.3648 ... [0.0000] ... 214748.3647
0x5042:019
Set velocity with offset
–
Read only
 
0x5042:021
Set velocity after measuring system alignment
–
Read only
 
0x5042:035
Set base velocity
–
Read only
 
0x5042:040
Slave set velocity
–
Read only