Velocity synchronization
The synchronism of master value and drive axis is established via a coupling mode.
The settings of the parameters Stretch factor numerator and Stretch factor denominator are only effective in Coupling mode = 0 effective.
Coupling via units or cycle lengths can be selected as the coupling mode. The coupling mode is configured via the Coupling mode parameter.
0x5041:030
0x5041:030|
Coupling mode 0x5041:030
|
Response/clutch factor
|
|
[0] unit clutching
|
Stretch factor numerator
0x5041:020Stretch factor denominator
0x5041:021 |
|
[1] Coupling via cycle length
|
Cycle length of the slave axis
0x500A:031
Cycle length of the master axis
0x500C:031 |
Example
|
Synchronism with equal cycle lengths 360/360
|
Synchronism with unequal cycle lengths 360/450
|
|
|
|
The coupling function synchronises the velocity of the drive to the Setpoint velocity with offset velocity value.
0x5042:019
0x5042:019The velocity value Setpoint velocity with offset contains the values:
–
Setpoint velocity after dimensional system adjustment
0x5042:021
0x5042:021–
Total velocity offset
0x5042:030
0x5042:030
|
Values to be specified
|
Parameter name
|
Parameter index
|
Bit
|
|
Acceleration
|
Acceleration of coupling
|
-
|
|
|
Coupling pressure
|
Jerk of coupling
|
-
|
|
|
Coupling
|
Control signals
|
Bit 16 = TRUE
|
|
|
Decoupling
|
Control signals
|
Bit 16 = FALSE
|
|
|
Deceleration
|
Deceleration of coupling
|
-
|
Fig. 1: Synchronism of signal flow
Fig. 2: Control bits and status bits
Fig. 3: Coupling process and decoupling process
The graphic shows the coupling process and the decoupling process from standstill to velocity 100 [units/s] and back to standstill.
Parameter
0x5041:020