Diagnostics

Parameter
Address
Name / setting range / [default setting]
Information
0x2C4F
Parameter CRC of motor encoder
–
Read only
 
Display of the cyclic redundancy check (CRC) of selected encoder parameters to detect changes in the feedback settings.
0x2DDF:005
Axis information: Detected module in slot A
–
Read only
 
Display of supported feedback system for the motor.
0
Product defined
1
No module
2
Resolver
3
SinCos/HIPERFACE®/SSI
4
SinCos/HIPERFACE®/SSI/TTL
5
I/O extension
6
SinCos/HIPERFACE®/SSI/TTL/EnDat®
7
I/O + HTL extension