Torque feedforward control
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2820:009
|
Holding brake control: Starting torque source
|
Setting of the source for the holding brake starting torque.
|
|
|
0
|
Last torque saved
|
The stopping value saved automatically during the last closing operation is used as starting torque.
|
|
|
1
|
Torque in 0x2820:010
|
The parameterised starting torque is used (0x2820:010).
|
|
|
0x2820:010
|
Holding brake control: Starting torque
-3276.8 ... [0.0] ... 3276.7 %
|
Setting of the feedforward control value for the automatic operation (0x2820:009 = 1).
|
|
|
0x2820:021
|
Holding brake control: Detected actual torque
–
Read only: x.x %
|
Display of the torque actual value that is used for the feedforward control. 0x2820:009 = 0
|
|