Manual brake control

The holding brake can be opened or closed manually regardless of its operating status and the operating state of the inverter. This function can be used, for example. to move the axis manually in the event of an error.
Note for inverters with Extended Safety:
Manual brake control is only possible if no error is active in the Extended Safety.
 
 
Details
 
The following settings are possible:
–
Open the holding brake:
 
–
The holding brake remains open until it closed again manually.
 
 
–
Close the holding brake.
 
–
Release the holding brake for a fixed time by a start signal and then apply it automatically:
 
–
Time for "Brake released": 0x2820:019
 
–
Start signal: 0x2820:020, bit 0 = 1
 
–
After the time has elapsed → bit 0 = 0
 
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2820:011
Holding brake control: Override of the brake control
Mode for override or forced opening/closing of the holding brake irrespective of the operating mode.
In the event of an error and activated function for forced opening, the brake is not applied.
0
No override active
Mode for override or forced opening/closing of the holding brake irrespective of the operating mode.
1
Open brake
–
In the event of an error and activated function for forced opening, the brake is not applied.
 
2
Close brake
3
Test pulse
0x2820:020
Holding brake control: Brake control word
0x00 ... [0x00] ... 0xFF
Control word for the holding brake.
Bit  0
Transmit test signal