Jerk limitation

Via the max. acceleration change that can be set in parameter 0x2945 C00274, the change of the setpoint torque can be limited for jerk limitation. Hence, sudden torque step changes can be avoided. The entire speed characteristic is smoothed.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2945
Torque setpoint jerk limitation
0.1 ... [400.0] ... 400.0
Setting of the maximum acceleration change.