Technology Application

In the "Technology application" dialogue of the
»
EASY Starter
«
software, the parameter Application selection shows which technology application is active. The technology application can be modified in this dialogue. 0x4000
 
Parameter
Address
Name / setting range / [default setting]
Information
0x4000
Application selection
–
Setting can only be changed if the inverter is disabled.
 
0
CiA 402
1
"CiA 402 advanced" technology application
5
10
"Speed Control" technology application
20
"Table Positioning" technology application
40
"Electronic Gearbox" technology application
41
"Sync and Correction" technology application
50
"Winder Dancer" technology application
51
"Winder Tension" technology application
10000
"User" technology application
0x2824
Control via PDO/Application
–
Setting can only be changed if the inverter is disabled.
 
Selection of how the inverter is controlled.
0
Flexible I/O configuration
1
Keypad